Diagnostic Accuracy of Oxygen Desaturation Index for Sleep-Disordered Breathing in Patients With Diabetes.
Аннотация
BACKGROUND
Polysomnography (PSG) is the gold standard for diagnosis of sleep-disordered breathing (SDB). But it is impractical to perform PSG in all patients with diabetes. The objective was to develop a clinically easy-to-use prediction model to diagnosis SDB in patients with diabetes.
METHODS
A total of 440 patients with diabetes were recruited and underwent overnight PSG at West China Hospital. Prediction algorithms were based on oxygen desaturation index (ODI) and other variables, including sex, age, body mass index, Epworth score, mean oxygen saturation, and total sleep time. Two phase approach was employed to derivate and validate the models.
RESULTS
ODI was strongly correlated with apnea-hypopnea index (AHI) (rs = 0.941). In the derivation phase, the single cutoff model with ODI was selected, with area under the receiver operating characteristic curve (AUC) of 0.956 (95%CI 0.917-0.994), 0.962 (95%CI 0.943-0.981), and 0.976 (95%CI 0.956-0.996) for predicting AHI ≥5/h, ≥15/h, and ≥30/h, respectively. We identified the cutoff of ODI 5/h, 15/h, and 25/h, as having important predictive value for AHI ≥5/h, ≥15/h, and ≥30/h, respectively. In the validation phase, the AUC of ODI was 0.941 (95%CI 0.904-0.978), 0.969 (95%CI 0.969-0.991), and 0.949 (95%CI 0.915-0.983) for predicting AHI ≥5/h, ≥15/h, and ≥30/h, respectively. The sensitivity of ODI ≥5/h, ≥15/h, and ≥25/h was 92%, 90%, and 93%, respectively, while the specificity was 73%, 89%, and 85%, respectively.
CONCLUSIONS
ODI is a sensitive and specific tool to predict SDB in patients with diabetes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.