MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d5nh00230c

Медицинская библиотека · Nanoscale horizons · 2025

Influence of hydrophilic polymers on the accelerated blood clearance of mRNA lipid nanoparticles upon repeated administration.

Hassanel Dayangku Nordiyana B P, Ju Yi, Takanashi Asuka, Algarni Azizah, Lee Chee Leng, Kent Stephen J, Pouton Colin W, Pilkington Emily H

СтатьяПеревод в очереди

Аннотация

mRNA lipid nanoparticles (LNPs) have emerged as a leading delivery system for mRNA-based vaccines and therapeutics. However, a significant limitation of this system is the presence of poly(ethylene) glycol (PEG). It is widely known that repeated doses of PEG-based therapeutics can induce an anti-PEG antibody response, leading to the accelerated blood clearance (ABC) of LNP therapeutics requiring frequent dosing, as anti-PEG antibodies have been found present in a large proportion of the population. To address this issue, we developed a mouse model for LNP clearance after a repeated dose. We then synthesised LNPs with the PEG component replaced by a library of hydrophilic polymers: poly(oligo(ethylene glycol) methyl ether methacrylate) (POEGMA), POEGMA-methacrylic acid (POEGMA (-)), POEGMA-2-(dimethylamino)ethyl methacrylate (POEGMA (+)), poly(N,N-dimethylacrylamide) (PDMA), and poly(N-(2-hydroxypropyl) methacrylamide) (PHPMA). Our results demonstrated that all three POEGMA LNPs, especially POEGMA (+) LNPs, exhibited minimal ABC effect after two weekly doses; in contrast, PDMA LNPs demonstrated significantly lower clearance in the presence of anti-PEG antibodies. This study highlights the potential of PEG-free polymer-LNPs as promising mRNA carriers that avoid rapid clearance with repeated administration.

Для цитирования: Hassanel Dayangku Nordiyana B P, Ju Yi, Takanashi Asuka, Algarni Azizah, Lee Chee Leng, Kent Stephen J, Pouton Colin W, Pilkington Emily H. Influence of hydrophilic polymers on the accelerated blood clearance of mRNA lipid nanoparticles upon repeated administration.. Nanoscale horizons. 2025. DOI: 10.1039/d5nh00230c.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.