MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.70345

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2026

AI-Powered Gradient Echo Plural Contrast Imaging (AI-GEPCI)-A Comprehensive Neurological Protocol From a Single MRI Scan.

Lewis Jeramy, Goyal Manu S, Wu Gregory F, Hu Yuyang, Sukstanskii Alexander L, Kothapalli Satya V V N, Cross Anne H, Kamilov Ulugbek, Yablonskiy Dmitriy A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

MRI is essential for diagnosing and monitoring neurological diseases. Conventional protocols require multiple sequences to obtain complementary contrasts, increasing scan time, cost, and tolerability. Generating multiple contrasts from a single acquisition may streamline workflow while maintaining clinical utility.

PURPOSE: To train attention-based convolutional neural networks (ACNNs) to generate clinical-quality Fluid-Attenuated-Inversion-Recovery (FLAIR), Magnetization-Prepared-Rapid-Gradient-Echo (MPRAGE), R2* maps, and derived contrasts from a single Gradient Echo Plural Contrast Imaging (GEPCI) acquisition.

STUDY TYPE: Retrospective.

POPULATION: 43 MRI scans from individuals with multiple sclerosis (25/18 F/M, 49 ± 11 years-of-age).

FIELD STRENGTH/SEQUENCE: 3 T MRI, 3D GEPCI, MPRAGE, and FLAIR.

ASSESSMENT: Technical quality of AI-generated contrasts was evaluated against directly acquired MRI using structural similarity index (SSIM). Clinical image quality was assessed by physicians. Lesion volumes and counts were obtained using automated segmentation.

STATISTICAL TESTS: One-sample one-sided Wilcoxon signed-rank test was used to establish the clinical quality of images. Agreement between native- and AI-derived lesion volume and lesion count measurements was assessed using intraclass correlation coefficients (ICC). Quantitative accuracy for R2* maps was evaluated using normalized root-mean-square error (NRMSE).

RESULTS

AI-generated FLAIR and MPRAGE achieved mean SSIM values of 0.923 ± 0.028 and 0.935 ± 0.022, respectively. Generated R2* maps achieved a mean SSIM of 0.996 ± 0.006 and NRMSE of 0.031 ± 0.020. Physicians-assigned mean clinical quality ratings of 4.2 for GEPCI-FLAIR and 4.5 for GEPCI-MPRAGE exceeded the 4.0 clinical standard on a 1-to-5 scale. Lesion volume and count comparisons from automated segmentation showed strong agreement between AI-generated and ground-truth measurements: R2 = 0.988 and R2 = 0.933, ICC = 0.988 and ICC = 0.967, respectively.

DATA

CONCLUSION

AI-GEPCI generated multiple clinically relevant MRI contrasts from a single GEPCI acquisition with high similarity to corresponding acquired images, supporting high-quality, intrinsically co-registered multi-contrast brain evaluation.

EVIDENCE LEVEL: 2.

TECHNICAL EFFICACY: Stage 1.

Для цитирования: Lewis Jeramy, Goyal Manu S, Wu Gregory F, Hu Yuyang, Sukstanskii Alexander L, Kothapalli Satya V V N, Cross Anne H, Kamilov Ulugbek, Yablonskiy Dmitriy A. AI-Powered Gradient Echo Plural Contrast Imaging (AI-GEPCI)-A Comprehensive Neurological Protocol From a Single MRI Scan.. Journal of magnetic resonance imaging : JMRI. 2026. DOI: 10.1002/jmri.70345.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.