MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.31022

Медицинская библиотека · The Laryngoscope · 2023

Intra-cochlear Flushing Reduces Tissue Response to Cochlear Implantation.

Razmovski Tayla, Brody Kate M, Stathopoulos Dimitra, Zhang Dongcheng, Cho Ellie, Hampson Amy J, Collins Aaron, Bester Christofer, O'Leary Stephen

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Intraoperative trauma leading to bleeding during cochlear implantation negatively impacts residual hearing of cochlear implant recipients. There are no clinical protocols for the removal of blood during implantation, to reduce the consequential effects such as inflammation and fibrosis which adversely affect cochlear health and residual hearing. This preclinical study investigated the implementation of an intra-cochlear flushing protocol for the removal of blood.

METHODS

Three groups of guinea pigs were studied for 28 days after cochlear implantation; cochlear implant-only (control group); cochlear implant with blood injected into the cochlea (blood group); and cochlear implant, blood injection, and flushing of the blood from the cochlea intraoperatively (flush group). Auditory brainstem responses (ABRs) in addition to tissue response volumes were analyzed and compared between groups.

RESULTS

After implantation, the blood group exhibited the highest ABR thresholds when compared to the control and flush group, particularly in the high frequencies. On the final day, the control and blood group had similar ABR thresholds across all frequencies tested, whereas the flush group had the lowest thresholds, significantly lower at 24 kHz than the blood and control group. Analysis of the tissue response showed the flush group had significantly lower tissue responses in the basal half of the array when compared with the blood and control group.

CONCLUSIONS

Flushing intra-cochlear blood during surgery resulted in better auditory function and reduced subsequent fibrosis in the basal region of the cochlea. This finding prompts the implementation of a flushing protocol in clinical cochlear implantation.

LEVEL OF EVIDENCE: N/A Laryngoscope, 134:1410-1416, 2024.

Для цитирования: Razmovski Tayla, Brody Kate M, Stathopoulos Dimitra, Zhang Dongcheng, Cho Ellie, Hampson Amy J, Collins Aaron, Bester Christofer, O'Leary Stephen. Intra-cochlear Flushing Reduces Tissue Response to Cochlear Implantation.. The Laryngoscope. 2023. DOI: 10.1002/lary.31022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.