OBJECTIVE

Use of cell culture and conventional in vivo mammalian models to assess nerve regeneration across guidance conduits is resource-intensive. Herein we describe a high-throughput platform utilizing transgenic mice for stain-free axon visualization paired with rapid cryosection techniques for low-cost screening of novel bioengineered nerve guidance conduit performance.

METHODS

Interposition repair of sciatic nerve transection in mice expressing yellow fluorescent protein in peripheral neurons (Thy1.2 YFP-16) was performed with various bioengineered neural conduit compositions using a rapid sutureless entubulation technique under isoflurane anesthesia. Axonal ingrowth was assessed at 3 and 6 weeks using epifluorescent microscopy following cryosectioning.

RESULTS

Mean procedure time (incision-to-closure) was less than 2½ minutes. Direct operational costs of a 3-week experiment was calculated at $21.47 per animal. Tissue processing steps were minimized to aldehyde fixation, cryoprotection and sectioning, and rapid fluorescent dye staining for conduit visualization. Fluorescent microscopy readily resolved robust axonal sprouting at 3 weeks, with clear elucidation of ingrowth-permissive, semipermissive, or restrictive nerve guidance conduit environments.

CONCLUSION

A rapid and cost-efficient in vivo platform for screening of nerve guidance conduit performance has been described.

LEVEL OF EVIDENCE: NA. Laryngoscope, E392-E392, 2018.

Для цитирования: Mohan Suresh, Hernández Iván Coto, Wang Wenjin, Yin Kaiyang, Sundback Cathryn A, Wegst Ulrike G K, Jowett Nate. Fluorescent Reporter Mice for Nerve Guidance Conduit Assessment: A High-Throughput in vivo Model.. The Laryngoscope. 2018. DOI: 10.1002/lary.27439.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.