MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08037051.2017.1312279

Медицинская библиотека · Blood pressure · 2017

Office blood pressure measurements with oscillometric devices in adolescents: a comparison with home blood pressure.

Jardim Thiago Veiga, Gaziano Thomas A, Nascente Flávia Miquetichuc, Carneiro Carolina de Souza, Morais Polyana, Roriz Vanessa, Mendonça Karla Lorena, Póvoa Thaís Inácio Rolim, Barroso Weimar Kunz Sebba, Sousa Ana Luiza Lima, Jardim Paulo César Veiga

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: Compare multiple in office BP measurements in adolescents using an oscillometric device with out-of-office blood pressure measurements (home blood pressure monitoring - HBPM).

MATERIALS AND

METHODS

Office measurements were performed with validated semi-automatic devices twice (3 minutes interval) in two different moments (1 week apart), with a total of four readings. These BP readings were named R1, R2, R3 and R4 (following the sequence they were performed), FDM (mean of two readings on first day) and SDM (mean of two readings on second day) and SRM (R2-R4 means). The HBPM protocol included two day-time and two evening-time measurements over 6 days.

RESULTS

A total of 1024 students between 12 and 17 years were included (mean age 14.68 years; 52.4% females). The mean systolic blood pressure (SBP) values of R2, SDM and SRM were similar to HBPM values. Regarding diastolic blood pressure (DBP) HBPM value was different than R4. High SBP and DBP correlation coefficients with HBPM values were found for R2, SDM and SRM values.

CONCLUSION

The second office BP measurement performed with an oscilometric device in adolescents was comparable to HBPM values, suggesting that two office readings might be suitable to rule out hypertension in this age group.

Для цитирования: Jardim Thiago Veiga, Gaziano Thomas A, Nascente Flávia Miquetichuc, Carneiro Carolina de Souza, Morais Polyana, Roriz Vanessa, Mendonça Karla Lorena, Póvoa Thaís Inácio Rolim, Barroso Weimar Kunz Sebba, Sousa Ana Luiza Lima, Jardim Paulo César Veiga. Office blood pressure measurements with oscillometric devices in adolescents: a comparison with home blood pressure.. Blood pressure. 2017. DOI: 10.1080/08037051.2017.1312279.