MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15385744261447457

Медицинская библиотека · Vascular and endovascular surgery · 2026

Optimizing Contrast Agent Usage and Evaluating Clinical Safety via Dilution Technique in Endovascular Abdominal Aortic Aneurysm Repair.

Ki Yusuke, Kuratani Toru, Oga Yuki, Kudo Tomoaki

СтатьяПеревод в очереди

Аннотация

ObjectiveContrast-induced nephropathy remains a significant concern in patients undergoing endovascular aneurysm repair (EVAR), particularly those with pre-existing renal impairment. This study aimed to evaluate the feasibility and safety of using a one-quarter diluted contrast agent during EVAR to reduce contrast volume without compromising imaging quality or clinical outcomes.MethodsWe retrospectively reviewed EVAR procedures performed between July 2022 and September 2024. A total of 96 patients were included, with 50 receiving undiluted contrast and 46 receiving a one-quarter diluted solution. All procedures were conducted using the same angiographic system and protocol. Pixel values and signal-to-noise ratios (SNRs) were measured from digital subtraction angiography (DSA) images. Subjective image quality was independently evaluated by three vascular surgeons using a standardized 5-point scale. Postoperative type I/III endoleaks were identified on contrast-enhanced CT or ultrasound within 30 days. Statistical comparisons were performed using Welch's t-test, Mann-Whitney U test, chi-square test, or Fisher's exact test, as appropriate.ResultsProcedural success was achieved in all cases. The diluted group achieved a 70% reduction in contrast volume (19.8 ± 11.5 mL vs 67.7 ± 30.5 mL; P < .001). Pixel values (2.87 ± 8.75 vs 2.99 ± 5.59; P = .936), SNRs, and surgeon-rated image quality were comparable between groups. The incidence of type I/III endoleaks (2.0% vs 4.3%; P = .606) and radiation parameters did not differ significantly.ConclusionsUse of a one-quarter diluted contrast agent during EVAR provided image quality and safety comparable to undiluted contrast while significantly reducing contrast volume. This technique may represent a practical strategy to mitigate renal risk in patients with impaired kidney function.

Для цитирования: Ki Yusuke, Kuratani Toru, Oga Yuki, Kudo Tomoaki. Optimizing Contrast Agent Usage and Evaluating Clinical Safety via Dilution Technique in Endovascular Abdominal Aortic Aneurysm Repair.. Vascular and endovascular surgery. 2026. DOI: 10.1177/15385744261447457.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.