Медицинская библиотека · International journal of cardiology · 2003

Poor agreement between dipyridamole-stress technetium-99m-tetrofosmin myocardial perfusion single photon emission computed tomography and two-dimensional echocardiography in Kawasaki disease.

Fu Y C, Liu F Y, Tsai S C, Hwang B, Chi C S

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

To establish a noninvasive diagnostic method for early assessment of cardiac involvement in Kawasaki disease (KD), 28 children with KD were included in this study. Two-dimensional echocardiography (2D-Echo) to detect the aneurysms of coronary arteries (CA), as well as rest and dipyridamole-stress technetium-99m tetrofosmin (Tc-TF) myocardial perfusion single photon emission computed tomography (SPECT) to detect abnormal myocardial perfusion were performed in all of the 28 children with KD and to compare each other. The results showed that (1). 42.9% of cases had no aneurysm and 57.1% had significant aneurysms detected by 2D-Echo; (2). 42.9% of cases had normal perfusion and 57.1% of cases had abnormal myocardial perfusion assessed by Tc-TF myocardial perfusion SPECT; (3). 25.0% of cases showed both normal 2D-Echo and Tc-TF myocardial perfusion SPECT findings and 39.3% of cases showed both abnormal 2D-Echo and Tc-TF myocardial perfusion SPECT findings; and (4). there was poor agreement between 2D-Echo and Tc-TF myocardial perfusion SPECT findings (P>0.05). We concluded that poor agreement exists between aneurysms and abnormal myocardial perfusion detected by 2D-Echo and Tc-TF myocardial perfusion SPECT findings in patients with KD.

Для цитирования: Fu Y C, Liu F Y, Tsai S C, Hwang B, Chi C S. Poor agreement between dipyridamole-stress technetium-99m-tetrofosmin myocardial perfusion single photon emission computed tomography and two-dimensional echocardiography in Kawasaki disease.. International journal of cardiology. 2003. DOI: 10.1016/s0167-5273(02)00525-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.