MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transproceed.2021.08.013

Медицинская библиотека · Transplantation proceedings · 2021

Management of Acute Portal Vein Thrombosis With Serial Mechanical Thrombectomy and tPA in a Pediatric Liver Transplant Recipient: A Case Report.

Moreno Nicolas F, Hernandez J Alberto, Desai Moreshwar S, Upton Ashley, Koohmaraie Sarah, Goss Matthew B, Goss John A, Galvan N Thao N

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Acute portal vein thrombosis is a major cause of fulminant allograft failure in pediatric liver transplantation. Timely intervention is critical to save the graft and patient. Serial interventional radiologic management of this condition is scarcely reported in the literature.

CASE SUMMARY: A recently transplanted 17-year-old male presented to the emergency department with abdominal pain. Rising liver enzymes prompted discovery of a diffuse portal thrombus, which precipitated fulminant liver failure. The adolescent developed respiratory failure, vasodilatory shock, acute kidney injury, and hepatic encephalopathy, complicating treatment. Multiple interventions attempted to clear the thrombus, including interventional radiologic and medical therapies. Uniquely, a continuous infusion catheter was placed at the thrombosis, delivering local tissue plasminogen activator during a 5-day period. Upon thrombus clearance, the patient made a full recovery with no complications during 12 months of follow-up.

CONCLUSIONS

When used as a component of multidisciplinary management, continuous locally directed tissue plasminogen activator may be a useful tool for clearance of persistent portal vein thrombosis.

Для цитирования: Moreno Nicolas F, Hernandez J Alberto, Desai Moreshwar S, Upton Ashley, Koohmaraie Sarah, Goss Matthew B, Goss John A, Galvan N Thao N. Management of Acute Portal Vein Thrombosis With Serial Mechanical Thrombectomy and tPA in a Pediatric Liver Transplant Recipient: A Case Report.. Transplantation proceedings. 2021. DOI: 10.1016/j.transproceed.2021.08.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.