MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2009.11.003

Медицинская библиотека · Journal of shoulder and elbow surgery · 2010

Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation.

Schumer Ross A, Muckley Kara L, Markert Ronald J, Prayson Michael J, Heflin Jonathan, Konstantakos Emmanuel K, Goswami Tarun

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

HYPOTHESIS: Locking plates have emerged as the implant of choice for stabilization of proximal humeral fractures. The biomechanical properties of a locked plating system using smooth pegs vs threaded screws for fixation of the humeral head were compared to test the hypothesis that there would be no biomechanical difference between pegs and threaded screws.

MATERIALS AND

METHODS

Sixteen pairs of fresh frozen cadaveric humeri were randomized to have a surgical neck gap osteotomy stabilized with a locked plate using threaded screws (n=8) or smooth pegs (n=8). The intact contralateral humerus served as a control. Each specimen was tested with simultaneous cyclic axial compression (40 Nm) and torsion (both +/-2 Nm and +/-5 Nm) for 6000 cycles. All specimens were loaded to failure. Interfragmentary motion and load-displacement curves were analyzed to identify differences between the groups. Our data were then compared to previously published forces across the glenohumeral joint to provide evidence based recommendations for postoperative use of the shoulder.

RESULTS

There was a statistically significant difference between test specimens and their paired control (P < .001) in cyclic testing and load to failure. Differences between the smooth pegs and threaded screws were not statistically significant.

DISCUSSION: There is no biomechanical difference between locked smooth pegs and locked threaded screws for proximal fragment fixation in an unstable 2-part proximal humeral fracture model.

CONCLUSION

Our study contributes to the published evidence evaluating forces across the glenohumeral joint and suggests that early use of the affected extremity for simple activities of daily living may be safe. Use of the arm for assisted ambulation requiring a crutch, cane, walker, or wheelchair should be determined on a case-by-case basis.

Для цитирования: Schumer Ross A, Muckley Kara L, Markert Ronald J, Prayson Michael J, Heflin Jonathan, Konstantakos Emmanuel K, Goswami Tarun. Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation.. Journal of shoulder and elbow surgery. 2010. DOI: 10.1016/j.jse.2009.11.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.