MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/21501351251329887

Медицинская библиотека · World journal for pediatric & congenital heart surgery · 2025

Analysis of 112 Patients With Congenital Heart Disease Undergoing Cardiac Transplantation: Impact of Pretransplant Ventricular Assist Device.

Bleiweis Mark Steven, Gupta Dipankar, Fricker Frederick J, Philip Joseph, Peek Giles J, Stukov Yuriy, Coppola John-Anthony, Sharaf Omar M, Purlee Matthew S, Brown Colton D, Kugler Liam R, Neal Dan, Pietra Biagio Bill A, Jacobs Jeffrey Phillip

СтатьяПеревод в очереди

Аннотация

BackgroundWe reviewed our management strategy and outcome data for all 112 patients with congenital heart disease (CHD) who underwent cardiac transplantation at University of Florida from January 2011, to January 2022, and evaluated the impact of a pretransplant ventricular assist device (VAD).MethodsContinuous variables are presented as mean (SD); median [interquartile range] (range); categorical variables are presented as N (%). Univariable associations with long-term survival were assessed with Cox proportional hazards models. The impact of pretransplant VAD on survival was estimated with multivariable models.ResultsPretransplant VAD was present in 24 of 112 patients who underwent cardiac transplantation (21.4%). Patients with a VAD were younger (years): 3.0 (3.8); 1 [0.5,6] (0.1,14) versus 12.9 (14.9); 9 [0.6,19] (0.1,58), P = .008. More patients with a VAD had prior cardiac operations: 24 of 24 (100%) versus 71 of 88 (80.7%), P = .021 and were more likely to receive an ABO-incompatible transplant: 6 of 24 (25%) versus 7 of 88 (8%), P = .032.Univariable associations with long-term mortality include: Number of prior cardiac surgeries-hazard ratio (HR) multiplies by 1.2 for each additional surgery (1.02-1.44), P = .029.Pretransplant renal dysfunction - HR = 2.8 (1.21-6.68), P = .017.Cardiopulmonary bypass (CPB) time at transplant: HR multiplies by 1.1 for each 10 min increase above the minimum CPB time in this series (1.03-1.19), P = .008.In multivariable analysis, pretransplant VAD does not impact survival when controlling for each one of the factors shown in univariable analysis to be associated with long-term survival. Kaplan-Meier five-year survival (95% confidence interval) is 77.4% (68.4%-87.5%) for all patients; 76.5% (66.7%-87.9%) without pretransplant VAD and 84.3% (69.3%-99.9%) with pretransplant VAD (P = .436).ConclusionOur single-institution analysis of 112 patients with CHD undergoing cardiac transplantation over 11.25 years reveals similar survival in patients with (n = 24) and without (n = 88) pretransplant VAD. The presence of a pretransplant VAD is not a risk factor for survival after transplantation in patients with CHD.

Для цитирования: Bleiweis Mark Steven, Gupta Dipankar, Fricker Frederick J, Philip Joseph, Peek Giles J, Stukov Yuriy, Coppola John-Anthony, Sharaf Omar M, Purlee Matthew S, Brown Colton D, Kugler Liam R, Neal Dan, Pietra Biagio Bill A, Jacobs Jeffrey Phillip. Analysis of 112 Patients With Congenital Heart Disease Undergoing Cardiac Transplantation: Impact of Pretransplant Ventricular Assist Device.. World journal for pediatric & congenital heart surgery. 2025. DOI: 10.1177/21501351251329887.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.