MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0003-4975(98)00351-8

Медицинская библиотека · The Annals of thoracic surgery · 1998

Repair of congenital tricuspid valve abnormalities with artificial chordae tendineae.

Reddy V M, McElhinney D B, Brook M M, Silverman N H, Stanger P, Hanley F L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Congenital abnormalities of the tricuspid valve, including Ebstein's malformation, dysplasia, straddling, and those found in pulmonary atresia with intact septum and congenitally corrected transposition, are an uncommon cause of tricuspid regurgitation. Congenital tricuspid valve anomalies are found as a spectrum of disease in which both the leaflets and the subvalvar apparatus are often involved. Tricuspid valve repair is complicated in such patients because the chordae tendineae are often abnormally short and thick. Replacement or augmentation of chordae tendineae has proved to be a useful component of mitral valve repair. In the present report, we describe the techniques and results of chordal augmentation in the repair of congenital tricuspid valve abnormalities.

METHODS

Since July 1992, tricuspid valve repair has been performed in 5 children with severe tricuspid regurgitation secondary to congenital abnormalities of the tricuspid valve with significant chordal pathology. As a component of the repair, chordal replacement or augmentation was performed using expanded polytetrafluoroethylene suture.

RESULTS

Intraoperative and postoperative echocardiographic assessment showed good mobility of the tricuspid valve leaflets and trivial to mild tricuspid regurgitation. There were no complications and no early or late mortality. At follow-up of 34 to 60 months (median, 49 months), tricuspid valve function has remained excellent in 4 of the 5 patients. In the remaining patient, progressive regurgitation of the right ventricle to pulmonary artery allograft conduit has led to right ventricular dilatation, with a secondary increase in tricuspid regurgitation from trivial to moderate.

CONCLUSIONS

Chordal replacement or augmentation with expanded polytetrafluoroethylene suture is a useful technique in the repair of congenitally dysplastic tricuspid valves with abnormal chordal structures.

Для цитирования: Reddy V M, McElhinney D B, Brook M M, Silverman N H, Stanger P, Hanley F L. Repair of congenital tricuspid valve abnormalities with artificial chordae tendineae.. The Annals of thoracic surgery. 1998. DOI: 10.1016/s0003-4975(98)00351-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.