Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society · 2024

Intraoperative Neurophysiological Monitoring in Tethered Cord Syndrome Surgery: Predictive Values and Clinical Outcome.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Squintani Giovanna, Basaldella Federica, Badari Andrea, Rasera Andrea, Tramontano Vincenzo, Pinna Giampietro, Moscolo Fabio, Soda Christian, Ricci Umberto, Ravenna Giorgio, Sala Francesco

Аннотация

INTRODUCTION: "Tethered cord syndrome" (TCS) refers to a congenital abnormality associated with neurological signs and symptoms. The aim of surgery is to prevent or arrest their progression. This study reports a retrospective case series of tethered cord syndrome surgeries, supported by intraoperative neurophysiological monitoring.

METHODS: The case series comprises 50 surgeries for tethered cord syndrome in which multimodal intraoperative neurophysiological monitoring was performed using motor evoked potentials (transcranial motor evoked potentials [TcMEPs]), tibial nerve somatosensory evoked potentials (TNSEPs), and pudendal-anal reflex (PAR). The intraoperative neurophysiological monitoring results are reported and correlated with clinical outcomes.

RESULTS: Sensitivity, specificity, and negative predictive value were high for TcMEPs and TNSEPs, while PAR exhibited low sensitivity and positive predictive value but high specificity and negative predictive value. Fisher's exact test revealed a significant correlation between changes in TcMEPs, TNSEPs, and clinical outcome ( P < 0.000 and P = 0.049 respectively), but no correlation was detected between PAR and urinary/anal function ( P = 0.497).

CONCLUSIONS: While TcMEPs and TNSEPs were found to be reliable intraoperative neurophysiological monitoring parameters during tethered cord syndrome surgery, PAR had low sensitivity and positive predictive value probably because the reflex is not directly related to bladder function and because its multisynaptic pathway may be sensitive to anesthetics. New onset muscle weakness and sensory deficits were related to postoperative changes in TcMEPs and TNSEPs, whereas changes in PAR did not predict bladder/urinary impairment. Urinary deficits may be predicted and prevented with other neurophysiological techniques, such as the bladder-anal reflex.