MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/iembs.2007.4353591

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2007

Estimation of effects of visually-induced motion sickness using independent component analysis.

Abe Makoto, Yoshizawa Makoto, Sugita Norihiro, Tanaka Akira, Chiba Shigeru, Yambe Tomoyuki, Nitta Shin-ichi

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

To quantify the effect of visually-induced motion sickness on the autonomic nervous system, the authors previously proposed a new physiological index rho max representing the maximum cross-correlation coefficient between blood pressure variability and heart rate variability whose frequency components are limited to the Mayer wave band. However, rho max requires measurement of continuous blood pressure with an expensive and bulky measuring device. In the present study, an easier method for obtaining rho max with measurement of neither continuous blood pressure nor ECG but using finger photoplethysmography (PPG) only has been developed. A blood pressure-related parameter was extracted from the PPG by using the independent component analysis. Two experiments in which subjects performed the Valsalva maneuver and then they watched a swaying video image were carried out to evaluate the adequacy of the proposed method. The experimental results have shown that the proposed method worked successfully as good as the conventional method. This means that the proposed method can contribute to increase in the number of subjects because multiple subjects can be used even in a single experiment.

Для цитирования: Abe Makoto, Yoshizawa Makoto, Sugita Norihiro, Tanaka Akira, Chiba Shigeru, Yambe Tomoyuki, Nitta Shin-ichi. Estimation of effects of visually-induced motion sickness using independent component analysis.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2007. DOI: 10.1109/iembs.2007.4353591.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.