Association between short-term exposure to ambient air pollution and dementia mortality in Chinese adults.

Liu Tingting, Zhou Yun, Wei Jing, Chen Qi, Xu Ruijun, Pan Jingju, Lu Wenfeng, Wang Yaqi, Fan Zhaoyu, Li Yingxin, Xu Luxi, Cui Xiuqing, Shi Chunxiang, Zhang Lan, Chen Xi, Bao Wei, Sun Hong, Liu Yuewei

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Short-term exposure to ambient air pollution has been linked to an increased risk of mortality from a variety of causes, but its effects on mortality from dementia remain largely unknown.

OBJECTIVES

To investigate the association between short-term exposure to ambient air pollution and dementia mortality, and quantitatively assess the excess mortality.

METHODS

In this time-stratified case-crossover study, 47,108 dementia deaths were identified in Jiangsu province, China during 2015-2019. Exposure to particulate matter with an aerodynamic diameter ≤ 2.5 μm (PM2.5), PM10, sulfur dioxide (SO2), nitrogen dioxide (NO2), carbon monoxide (CO), and ozone (O3) was assessed by extracting daily concentrations from a validated grid dataset based on each subject's residential address. Conditional logistic regression models were applied for exposure-response analyses.

RESULTS

There were 47,108 case days and 159,852 control days during the study period. Each 10 μg/m3 increase of lag 04-day exposure to PM2.5, PM10, and NO2 was significantly associated with a 1.43 % (95 % CI: 0.77, 2.09 %), 1.06 % (0.59, 1.54 %), and 2.80 % (1.51, 4.10 %) increase in odds of dementia mortality, corresponding to an excess mortality of 4.87 %, 5.50 %, and 6.43 %, respectively. We estimated that reducing ambient air pollutant exposures to the WHO air quality guidelines would avoid up to 4.17 % of the dementia deaths, while the ambient air quality standards in China would only help avoid up to 0.39 %.

CONCLUSIONS

This study provides consistent evidence that short-term exposure to PM2.5, PM10, and NO2 is associated with increased odds of dementia mortality, which can be translated to a considerable excess mortality. Our findings highlight a potential approach to prevent deaths from dementia by reducing individual exposures to ambient air pollution, especially in areas with high levels of ambient air pollution.

Для цитирования: Liu Tingting, Zhou Yun, Wei Jing, Chen Qi, Xu Ruijun, Pan Jingju, Lu Wenfeng, Wang Yaqi, Fan Zhaoyu, Li Yingxin, Xu Luxi, Cui Xiuqing, Shi Chunxiang, Zhang Lan, Chen Xi, Bao Wei, Sun Hong, Liu Yuewei. Association between short-term exposure to ambient air pollution and dementia mortality in Chinese adults.. The Science of the total environment. 2022. DOI: 10.1016/j.scitotenv.2022.157860.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.