MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0029-1245428

Медицинская библиотека · Ultraschall in der Medizin (Stuttgart, Germany : 1980) · 2010

Volumetry of fetal hearts using 3D real-time matrix echocardiography - in vitro validation experiments and 3D echocardiographic studies in fetuses.

Herberg U, Lück S, Steinweg B, Brand M, Knies R, Geipel A, Trier H G, Breuer J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The aim of this study was to assess the feasibility, accuracy and reliability of 3D real-time echocardiography for fetal heart volumetry.

MATERIALS AND

METHODS

Fifty unselected and consecutive fetuses, including 14 with cardiac malformations, were scanned prospectively using real-time 3D matrix technology and 2D echocardiography to determine ventricular volumes. Small phantoms as well as modified balloons (0.5 - 20 ml) were used to assess the validity of 2D and 3D distance, area and volume calculations and to study potential sources of error during data acquisition and analysis. The data was evaluated by two blinded observers.

RESULTS

In vitro, real-time 3D and 2D underestimated the actual volumes by -5.49 % (3D) and -6.86 % (2D). The intraobserver and interobserver variability were excellent. In vivo, real-time 3D was superior to 2D with regard to intraobserver and interobserver variability (mean coefficient of variation 8.28 % (3D) versus 13.96 % (2D), and mean intraclass correlation coefficient 0.997 (3D) versus 0.885 (2D) for left ventricular volumes). Similar to in vitro, in vivo 2D volumes were calculated smaller than 3D volumes (mean difference -0.39 to -0.94 ml). The ventricular volumes and stroke volumes increased exponentially with gestation. Secondary to poor imaging windows in advanced gestation or inadequate delineation of endocardial borders in small hearts at less than 19 weeks, 3D data could not be analyzed sufficiently in 6 / 50 fetuses.

CONCLUSION

Real-time 3D using a matrix transducer is a feasible, reliable and valid method for volume determination in the fetus beyond 19 weeks of gestation. If compared to 2D, real-time 3D echocardiography provides improved accuracy of cardiac volumetry, decreases intraobserver and interobserver variability and is a promising tool for the accurate assessment of cardiac size and function.

Для цитирования: Herberg U, Lück S, Steinweg B, Brand M, Knies R, Geipel A, Trier H G, Breuer J. Volumetry of fetal hearts using 3D real-time matrix echocardiography - in vitro validation experiments and 3D echocardiographic studies in fetuses.. Ultraschall in der Medizin (Stuttgart, Germany : 1980). 2010. DOI: 10.1055/s-0029-1245428.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.