MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2011.09.072

Медицинская библиотека · The Annals of thoracic surgery · 2011

Permanent epicardial pacing in pediatric patients: 12-year experience at a single center.

Kwak Jae Gun, Kim Soo-Jin, Song Jin Young, Choi Eun Young, Lee Sang Yoon, Shim Woo Sup, Lee Chang-Ha, Lee Cheul, Park Chun Soo

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Permanent cardiac pacing is not often done in children, and when done is usually accomplished through epicardial pacing. We reviewed a 12-year experience with the implantation of epicardial pacemakers by our clinical group.

METHODS

Fifty-three patients who underwent their first implantation of an epicardial pacemaker before the age of 18 years and between 1997 and 2009 were included in our study. The mean age of the patients at the time of first pacemaker implantation was 5.7±4.8 years. Indications for pacemaker implantation included postoperative or congenital atrioventricular block and sinus node dysfunction. The patients underwent 105 operations for the replacement of pacemaker pulse generators and 75 operations for the replacement of pacemaker leads. The most commonly used generator mode was the rate-responsive accelerometer-based (DDDR) mode, which was used in 40.9% of the patients. We used more non-steroid-eluting leads (70.1%) than steroid-eluting leads (29.1%).

RESULTS

The overall duration of follow-up in the study was 8.0±4.5 years (range, 2.1 months to approximately 17.0 years). Freedom from the need for generator replacement was 98.0%, 60.7%, and 11.1% at 1, 5, and 8 years, respectively. A tendency toward early generator exhaustion was observed among younger patients (p=0.058). The generator mode used for pacing did not significantly affect generator longevity. Freedom from the need for lead replacement was 98.3%, 83.8%, and 63.6% at 1, 5, and 10 years, respectively. The mean longevity of the leads used in the study was 10.8±0.8 years. Neither patient age at the time of lead implantation nor type of lead significantly affected lead longevity.

CONCLUSIONS

Lead longevity was sufficiently long and did not vary significantly according to type of lead. Generator longevity was not affected by lead type, generator mode, or patient age at the time of pacemaker implantation.

Для цитирования: Kwak Jae Gun, Kim Soo-Jin, Song Jin Young, Choi Eun Young, Lee Sang Yoon, Shim Woo Sup, Lee Chang-Ha, Lee Cheul, Park Chun Soo. Permanent epicardial pacing in pediatric patients: 12-year experience at a single center.. The Annals of thoracic surgery. 2011. DOI: 10.1016/j.athoracsur.2011.09.072.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.