OBJECTIVE

To evaluate the clinical utility of time-resolved contrast-enhanced magnetic resonance angiography (MRA) in the evaluation of vascular orbital tumors.

METHODS

Retrospective medical record review of patients with vascular orbital lesions imaged with Time-Resolved Imaging of Contrast KineticS (TRICKS; GE Healthcare [Chalfont St Giles, England]) MRA, a noninvasive dynamic imaging modality.

RESULTS

Five patients with orbital vascular tumors were evaluated using TRICKS MRA. These included 1 patient with a cavernous hemangioma, 2 patients with orbital varices, 1 patient with an orbitocutaneous arteriovenous malformation, and 1 patient who had a solitary fibrous tumor with features of a hemangiopericytoma. In 2 patients, diagnoses were altered as a result of TRICKS MRA. In addition, a young patient with a large orbitocutaneous arteriovenous malformation involving the ophthalmic artery was followed perioperatively and noninvasively using TRICKS MRA, which produced exquisite images and added substantial value in the care of these patients.

CONCLUSION

Dynamic MRA in the form of TRICKS is a newly available imaging modality with great potential for improving the evaluation and management of patients with complex orbital tumors.

Для цитирования: Kahana Alon, Lucarelli Mark J, Grayev Allison M, Van Buren Jeremy J, Burkat Cat N, Gentry Lindell R. Noninvasive dynamic magnetic resonance angiography with Time-Resolved Imaging of Contrast KineticS (TRICKS) in the evaluation of orbital vascular lesions.. Archives of ophthalmology (Chicago, Ill. : 1960). 2007. DOI: 10.1001/archopht.125.12.1635.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.