MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12985-024-02430-x

Медицинская библиотека · Virology journal · 2024

Evaluation of the FPMC respiratory panel for detection of respiratory tract pathogens in nasopharyngeal swab and sputum specimens.

Xue Li, Zhu Jianhong, Lei Ke, Liu Zeshi, Tang Yiwei, Zhong Bo, Gao Ning, Xiong Chaoliang, Lei Jing, Tian Ying, Zhou Weixiao, Feng Nan, Zhang Xue, Chen Dong, Li Jing, Geng Yan

СтатьяОценочное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The performance of the new Respiratory Pathogen panel (fluorescent probe melting curve, FPMC) for the qualitative detection of 12 organisms (chlamydia pneumoniae, mycoplasma pneumoniae, adenovirus, influenza A virus, influenza B virus, parainfluenza virus, rhinovirus, etc.) was assessed.

METHODS

Prospectively collected nasopharyngeal swab (NPS) and sputum specimens (n = 635) were detected by using the FPMC panel, with the Sanger sequencing method as the comparative method.

RESULTS

The overall percent concordance between the FPMC analysis method and the Sanger sequencing method was 100% and 99.66% for NPS and sputum specimens, respectively. The FPMC testified an overall positive percent concordance of 100% for both NPS and sputum specimens. The FPMC analysis method also testified an overall negative percent concordance of 100% and 99.38% for NPS and sputum specimens, respectively.

CONCLUSIONS

The FPMC analysis method is a stable and accurate assay for rapid, comprehensive detecting for respiratory pathogens.

Для цитирования: Xue Li, Zhu Jianhong, Lei Ke, Liu Zeshi, Tang Yiwei, Zhong Bo, Gao Ning, Xiong Chaoliang, Lei Jing, Tian Ying, Zhou Weixiao, Feng Nan, Zhang Xue, Chen Dong, Li Jing, Geng Yan. Evaluation of the FPMC respiratory panel for detection of respiratory tract pathogens in nasopharyngeal swab and sputum specimens.. Virology journal. 2024. DOI: 10.1186/s12985-024-02430-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.