MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2016.12.087

Медицинская библиотека · International journal of cardiology · 2016

Pressure-volume loop-derived cardiac indices during dobutamine stress: a step towards understanding limitations in cardiac output in children with hypoplastic left heart syndrome.

Wong James, Pushparajah Kuberan, de Vecchi Adelaide, Ruijsink Bram, Greil Gerald F, Hussain Tarique, Razavi Reza

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Children with a single systemic right ventricle, such as in hypoplastic left heart syndrome (HLHS), frequently experience reduced exercise capacity. Elucidating the causes could help with optimising treatment strategies.

METHODS

Prospective data from 10 consecutive symptomatic patients with HLHS undergoing clinical cardiac magnetic resonance with catheterisation (XMR) were analysed. Mean age 8.6years (range 3.5-11.6years), mean time since Fontan completion 5.5years. MR-compatible catheters were placed in the systemic right ventricle and branch pulmonary arteries to record pressures at rest, with dobutamine infusion at 10mcg/kg/min and at 20mcg/kg/min. Cine short-axis stacks of the ventricle were performed at each condition and used to construct pressure-volume loops.

RESULTS

Compared to rest, cardiac index increased with low-dose dobutamine (p<0.01) with no further rise at peak stress despite a further, albeit, blunted rise in heart rate (p=0.002). A fall in stroke volume occurred (p=0.014) despite good contractility (74% increase, p=0.045) and a well-coupled ventriculo-arterial ratio. End-diastolic pressure and early active relaxation, markers of diastolic function, were normal at rest. However, preload fell at peak stress (p<0.008) while pulmonary vascular resistance (PVR) was low throughout. This group of HLHS patients demonstrated a fall in SV at peak stress, coinciding with a fall in preload.

CONCLUSIONS

Markers of systolic and diastolic function remained normal. Failure to adequately fill the ventricle implies a ceiling of maximal flow through the Fontan circuit despite low PVR.

Для цитирования: Wong James, Pushparajah Kuberan, de Vecchi Adelaide, Ruijsink Bram, Greil Gerald F, Hussain Tarique, Razavi Reza. Pressure-volume loop-derived cardiac indices during dobutamine stress: a step towards understanding limitations in cardiac output in children with hypoplastic left heart syndrome.. International journal of cardiology. 2016. DOI: 10.1016/j.ijcard.2016.12.087.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.