BACKGROUND

A research study in the Netherlands showed that general ultrasound (US) screening was cost-effective in the detection of developmental dysplasia of the hip (DDH). This study was followed by a pilot implementation study. Part of this pilot implementation study is to investigate whether professionals of the infant health care (IHC) system, with no previous US experience, would be able to perform US of the hip.

OBJECTIVE

This study looks at health care worker ability to classify US images into a modified Graf system.

MATERIALS AND

METHODS

After theoretical and practical training, seven nurses and physicians of the participating IHC centers reported their findings on sonographic images of 80 children. This was repeated five months later. From the two evaluation moments the intraobserver agreement and the interobserver agreement was determined.

RESULTS

The average estimated interobserver Cohen's kappa for both sessions was for nurses 0.6 and for physicians 0.5. The second evaluation showed a decrease from an average of 4.3% missed cases per screener to 2.3% and an increase of an average of 5% false positives per screener to 9.1%.

CONCLUSION

The inter- and intra-observer agreement is comparable to similar studies in which the participants had a professional background in US examination. The level of agreement of the trainees in the perspective of the screening process was considered sufficient for the pilot implementation project.

Для цитирования: Ramwadhdoebe S, Sakkers R J B, Uiterwaal Cuno S P M, Boere-Boonekamp Magda M, Beek Frederik J A. Evaluation of a training program for general ultrasound screening for developmental dysplasia of the hip in preventive child health care.. Pediatric radiology. 2010. DOI: 10.1007/s00247-010-1689-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.