MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.cir.103.20.2476

Медицинская библиотека · Circulation · 2001

Noninvasive quantification of left-to-right shunt in pediatric patients: phase-contrast cine magnetic resonance imaging compared with invasive oximetry.

Beerbaum P, Körperich H, Barth P, Esdorn H, Gieseke J, Meyer H

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Blood flow can be quantified noninvasively by phase-contrast cine MRI (PC-MRI) in adults. Little is known about the feasibility of the method in children with congenital heart disease.

METHODS AND

RESULTS

In 50 children (mean age 6.2 years, range 1.1 to 17.7 years) with an atrial- or ventricular-level shunt, blood flow rate in the great vessels was determined by PC-MRI, and the ratio of pulmonary to aortic flow (Qp/Qs) was compared with Qp/Qs by oximetry. We found a difference of 2% and a range of -20% to +26% (limits of agreement, mean +/-2 SD). In another 7 children with congenital heart disease but no cardiac shunting (mean age 7.9 years, range 1.3 to 13.5 years), Qp/Qs by PC-MRI was 1.02 (SD +/-0.06). No difference between systemic venous and aortic flow volumes was found (range -17% to +20%, n=37). Blood flow through a secundum atrial septal defect as assessed by PC-MRI (n=24) overestimated the shunt compared with the difference between pulmonary and aortic flows. The mean difference between 3 repeated PC-MRI measurements in each location was 5.3% (SD +/-4.0%, n=522), demonstrating good precision. The interobserver variability was low. The accuracy of PC-MRI was confirmed by in vitro experiments.

CONCLUSIONS

Determination of Qp/Qs by PC-MRI in children is quick, safe, and reliable compared with oximetry. Systemic venous flow can be quantified by PC-MRI, whereas through-plane shunt measurement within an atrial septal defect is inaccurate.

Для цитирования: Beerbaum P, Körperich H, Barth P, Esdorn H, Gieseke J, Meyer H. Noninvasive quantification of left-to-right shunt in pediatric patients: phase-contrast cine magnetic resonance imaging compared with invasive oximetry.. Circulation. 2001. DOI: 10.1161/01.cir.103.20.2476.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.