m+Medelevator.RU
← Поиск публикаций
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2023

Programming Levels and Speech Perception in Pediatric Cochlear Implant Recipients With Enlarged Vestibular Aqueduct or GJB2 Mutation.

СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jahn Kelly N, Morse-Fortier Charlotte, Griffin Amanda M, Faller David, Cohen Michael S, Kenna Margaret A, Doney Elizabeth, Arenberg Julie G

Аннотация

OBJECTIVE: To determine the relationship between hearing loss etiology, cochlear implant (CI) programming levels, and speech perception performance in a large clinical cohort of pediatric CI recipients.

STUDY DESIGN: Retrospective chart review.

SETTING: Tertiary care hospitals.

PATIENTS: A total of 136 pediatric CI recipients (218 ears) were included in this study. All patients had diagnoses of either enlarged vestibular aqueduct (EVA) or GJB2 (Connexin-26) mutation confirmed via radiographic data and/or genetic reports. All patients received audiologic care at either Boston Children's Hospital or Massachusetts Eye and Ear in Boston, MA, between the years 1999 and 2020.

MAIN OUTCOME MEASURES: Electrode impedances and programming levels for each active electrode and speech perception scores were evaluated as a function of etiology (EVA or GJB2 mutation).

RESULTS: Children with EVA had significantly higher impedances and programming levels (thresholds and upper stimulation levels) than the children with GJB2 mutation. Speech perception scores did not differ as a function of etiology in this sample; rather, they were positively correlated with duration of CI experience (time since implantation).

CONCLUSIONS: Differences in electrode impedances and CI programming levels suggest that the electrode-neuron interface varies systematically as a function of hearing loss etiology in pediatric CI recipients with EVA and those with GJB2 mutation. Time with the CI was a better predictor of speech perception scores than etiology, suggesting that children can adapt to CI stimulation with experience.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты