[High throughput screening method of potassium channel regulators].

Pan Ya-ping, Xu Xiang-hua, Wang Xiao-liang

Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: To discover new regulators of potassium channel, an in vitro assay based on DiBAC4 (3) to determine the fluorescence was established for high throughput screening.

METHODS

A cell-based 96-well format fluorescence assay using DiBAC4 (3) in cultured PC12 cells was described. Cells were loaded with 5 mumol.L-1 DiBAC4 (3) and incubated at 37 degrees C for 30 min before adding KCl or several known potassium channel regulators. The cellular DiBAC4 (3) fluorescence responce was then detected. The fluorescence changes can be used to evaluate membrane potential changes, which are determined mainly by potassium channels.

RESULTS

Extracellular high K(+)-induced depolarization and several potassium channel blockers including 4-AP, TEA, E-4031, glibenclamide, quinidine and nifedipine all evoked increases in DiBAC4 (3) fluorescence response. The potassium channel opener, cromakalim, evoked decrease in DiBAC4 (3) fluorescence response. The fluorescence changes of 4-AP, TEA, glibenclamide, nifedipine and cromakalim were in a concentration-dependent manner. In 76 compounds screened by using the established DiBAC4 (3)-based assay, 9 compounds were found to change the fluorescence dose-dependently. Patch clamp technique is needed to further testify and screen their actions on potassium currents.

CONCLUSION

The DiBAC4 (3)-based assay is easily operated, economical and repeatable. So, it can be performed by high throughput screening for potassium channel regulators.

Для цитирования: Pan Ya-ping, Xu Xiang-hua, Wang Xiao-liang. [High throughput screening method of potassium channel regulators].. Yao xue xue bao = Acta pharmaceutica Sinica. 2004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.