MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/aam.aam_81_23

Медицинская библиотека · Annals of African medicine · 2024

Diagnostic Accuracy of Serum Glycosylated Fibronectin in Prediction of Preeclampsia: A Nested Case-Control Study.

Sachan Rekha, Sachan Pushpa Lata, Ghayyur Nazrana, Patel Munna Lal, Ali Wahid

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Preeclampsia is a life-threatening complication of pregnancy that occurs in approximately 7% of all pregnancies. In India, the incidence of preeclampsia is 8%-10% and the prevalence is 5.4%, whereas the prevalence of hypertensive disorders of pregnancy is 7.8%.

AIM AND

OBJECTIVES

This study was aimed at evaluating the diagnostic accuracy of serum glycosylated fibronectin (S. GlyFn) in the prediction of preeclampsia.

METHODS

A nested case-control study was carried out for 16 months in the department of obstetrics and gynecology. A total of 240 women were recruited and followed after written consent and ethical clearance. Six were lost to follow-up, 15 had second-trimester abortions (excluded from the study), and 32 women developed hypertensive disorders of pregnancy (cases), out of which 1 woman developed antepartum eclampsia, 10 women developed preeclampsia with severe features, and 21 women developed preeclampsia without severe features. One hundred and eighty-seven women remained normotensive throughout the pregnancy until 6 weeks postpartum. After randomization, out of these samples, 54 were analyzed and considered controls. Levels of S. GlyFn were estimated using an ELISA kit using the ELISA technique.

RESULTS

The mean S. GlyFn level was significantly higher at the time of enrollment among those women who later developed preeclampsia (127.59 ± 27.68 ng/m) as compared to controls (107.79-53.51 ng/mL). GlyFn at a cutoff value of 126.70 ng/mL significantly (P = 0.034) discriminates cases of preeclampsia with severe features from healthy controls with a sensitivity of 90.00%, a specificity of 63.00%, a 31.03% positive predictive value, and 97.14% negative predictive value.

CONCLUSION

S. GlyFn, at a cutoff value of 126.70 ng/mL, had good sensitivity to discriminate PE from normotensive and was also a good prognostic marker.

Для цитирования: Sachan Rekha, Sachan Pushpa Lata, Ghayyur Nazrana, Patel Munna Lal, Ali Wahid. Diagnostic Accuracy of Serum Glycosylated Fibronectin in Prediction of Preeclampsia: A Nested Case-Control Study.. Annals of African medicine. 2024. DOI: 10.4103/aam.aam_81_23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.