m+Medelevator.RU
← Поиск публикаций
Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2020

Diagnosis of sleep apnea without sensors on the patient's face.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sabil AbdelKebir, Marien Caroline, LeVaillant Marc, Baffet Guillaume, Meslier Nicole, Gagnadoux Frédéric

Аннотация

STUDY OBJECTIVES: Thermistors, nasal cannulas, and respiratory inductance plethysmography (RIP) are the recommended reference sensors of the American Academy of Sleep Medicine (AASM) for the detection and characterization of apneas and hypopneas; however, these sensors are not well tolerated by patients and have poor scorability. We evaluated the performance of an alternative method using a combination of tracheal sounds (TSs) and RIP signals.

METHODS: Consecutive recordings of 70 adult patients from the Pays de la Loire Sleep Cohort were manually scored in random order using the AASM standard signals and the combination TS and RIP signals, without respiratory sensors placed on the patient's face. The TS-RIP scoring used the TS and RIP-flow signals for detection of apneas and hypopneas, respectively, and the suprasternal pressure and RIP belt signals for the characterization of apneas.

RESULTS: Sensitivity and specificity of the TS-RIP combination were 96.21% and 91.34% for apnea detection and 89.94% and 93.25% for detecting hypopneas, respectively, with a kappa coefficient of 0.87. For the characterization of apneas, sensitivity and specificity were 98.67% and 96.17% for obstructive apneas, 92.66% and 99.36% for mixed apneas, and 96.14% and 98.89% for central apneas, respectively, with a kappa coefficient of 0.94. The TS-RIP scoring revealed a high agreement for classifying obstructive sleep apnea into severity classes (none, mild, moderate, and severe obstructive sleep apnea) with a Cohen's kappa coefficient of 0.96.

CONCLUSIONS: Compared with the AASM reference sensors, the TS-RIP combination allows reliable noninvasive detection and characterization of respiratory events with a high degree of sensitivity and specificity. TS-RIP combination could be used for diagnosis of obstructive sleep apnea in adults, either as an alternative to the AASM sensors or in combination with the recommended AASM sensors.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты