Diagnostic value of 18F-FDG PET-CT in detecting malignant peripheral nerve sheath tumors among adult and pediatric neurofibromatosis type 1 patients.

Geitenbeek Ritch T J, Martin Enrico, Graven Laura H, Broen Martijn P G, Anten Monique H M E, van der Pol Jochem A J, Verhoef Cornelis, Taal Walter

СтатьяПеревод в очереди

Аннотация

PURPOSE: Detecting malignant peripheral nerve sheath tumors (MPNSTs) remains difficult. 18F-FDG PET-CT has been shown helpful, but ideal threshold values of semi-quantitative markers remain unclear, partially because of variation among scanners. Using EU-certified scanners diagnostic accuracy of ideal and commonly used 18F-FDG PET-CT thresholds were investigated and differences between adult and pediatric lesions were evaluated.

METHODS

A retrospective cohort study was performed including patients from two hospitals with a clinical or radiological suspicion of MPNST between 2013 and 2019. Several markers were studied for ideal threshold values and differences among adults and children. A diagnostic algorithm was subsequently developed.

RESULTS

Sixty patients were included (10 MPNSTs). Ideal threshold values were 5.8 for SUVmax (sensitivity 0.70, specificity 0.92), 5.0 for SUVpeak (sensitivity 0.70, specificity 0.97), 1.7 for TLmax (sensitivity 0.90, specificity 0.86), and 2.3 for TLmean (sensitivity 0.90, specificity 0.79). The standard TLmean threshold value of 2.0 yielded a sensitivity of 0.90 and specificity of 0.74, while the standard SUVmax threshold value of 3.5 yielded a sensitivity of 0.80 and specificity of 0.63. SUVmax and adjusted SUV for lean body mass (SUL) were lower in children, but tumor-to-liver ratios were similar in adult and pediatric lesions. Using TLmean > 2.0 or TLmean < 2.0 and SUVmax > 3.5, a sensitivity and specificity of 1.00 and 0.63 can be achieved.

CONCLUSION

18F-FDG PET-CT offers adequate accuracy to detect MPNSTs. SUV values in pediatric MPNSTs may be lower, but tumor-to-liver ratios are not. By combining TLmean and SUVmax values, a 100% sensitivity can be achieved with acceptable specificity.

Для цитирования: Geitenbeek Ritch T J, Martin Enrico, Graven Laura H, Broen Martijn P G, Anten Monique H M E, van der Pol Jochem A J, Verhoef Cornelis, Taal Walter. Diagnostic value of 18F-FDG PET-CT in detecting malignant peripheral nerve sheath tumors among adult and pediatric neurofibromatosis type 1 patients.. Journal of neuro-oncology. 2022. DOI: 10.1007/s11060-021-03936-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.