MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transproceed.2018.08.029

Медицинская библиотека · Transplantation proceedings · 2018

Use of Intraoperative Duplex Ultrasound and Resistance Index Reduces Complications in Living Renal Donor Transplantation.

Bejic M, Déglise S, Venetz J P, Nseir G, Dubuis C, Saucy F, Berard X, Meuwly J Y, Corpataux J M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The treatment of choice in end-stage renal disease is transplantation. Hemodynamic disturbances can evoke graft loss, while early ultrasound identification of vascular problems improves outcome. The aim of this study was to identify differences in postoperative complications with and without systematic intraoperative Doppler ultrasound use.

METHODS

The primary outcome was the postoperative rate of complications and the secondary aim was to find a predictive resistance index cut-off value, which would show where surgical reintervention was necessary. Over a 10-year period, 108 renal transplants were performed from living donors at our institution. In group 1 (n = 67), intraoperative duplex ultrasound and intraparenchymatous resistance index measurements assessed patients, while in group 2 (n = 41), no ultrasound was performed.

RESULTS

There were no intergroup differences in the overall postoperative complication rate or in benefit to graft or patient survival with Doppler use. However, significantly more vascular complications (10% vs 0%, P = .02) and more acute rejections (37% vs 10%) occurred in group 2 than in group 1. Therefore, an intraoperative cut-off value of the resistance index 0.5 was proposed to justify immediate surgical revision.

CONCLUSIONS

This is the first report demonstrating benefits of systematic intraoperative Doppler ultrasound on postoperative complications in renal transplantation from living donors. Our results support surgical revision with a resistance index <0.5.

Для цитирования: Bejic M, Déglise S, Venetz J P, Nseir G, Dubuis C, Saucy F, Berard X, Meuwly J Y, Corpataux J M. Use of Intraoperative Duplex Ultrasound and Resistance Index Reduces Complications in Living Renal Donor Transplantation.. Transplantation proceedings. 2018. DOI: 10.1016/j.transproceed.2018.08.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.