Surgical site infection after total en bloc spondylectomy: risk factors and the preventive new technology.

Hayashi Hiroyuki, Murakami Hideki, Demura Satoru, Kato Satoshi, Yoshioka Katsuhito, Shinmura Kazuya, Yokogawa Noriaki, Ishii Takayoshi, Fang Xiang, Shirai Toshiharu, Tsuchiya Hiroyuki

СтатьяПеревод в очереди

Аннотация

BACKGROUND CONTEXT: Surgical site infection (SSI) associated with instruments remains a serious and common complication in patients who undergo total en bloc spondylectomy (TES). It is very important that the risk factors for SSI are known to prevent it.

PURPOSE: The purpose of the study was to identify independent risk factors for SSI after TES and evaluate the positive effect of iodine-supported spinal instruments in the prevention of SSI after TES.

STUDY

DESIGN

This is a retrospective clinical study.

PATIENT SAMPLE: One hundred twenty-five patients who underwent TES for vertebral tumor were evaluated.

OUTCOME MEASURES: Incidence rate of SSI, risk factors for SSI after TES, and safety of iodine-supported spinal instruments were the outcome measures.

METHODS

Risk factors for SSI were analyzed using logistic regression. In recent 69 patients with iodine-supported spinal instruments, the thyroid hormone levels in the blood were examined to confirm if iodine from the implant influenced thyroid function. Postoperative radiological evaluations were performed regularly.

RESULTS

The rate of SSI was 6.4% (8/125 patients). By multivariate logistic regression, combined anterior and posterior approach and nonuse of iodine-supported spinal instruments were associated with an increased risk of SSI. The rate of SSI without iodine-supported spinal instruments was 12.5%, whereas the rate with iodine-supported spinal instruments was 1.4%. This difference was statistically significant. There were no detected abnormalities of thyroid gland function with the use of iodine-supported instruments. Among the 69 patients with iodine-supported spinal instruments, 2 patients required additional surgery because of instrument failure. However, there were no obvious involvements with the use of iodine-supported spinal instruments.

CONCLUSIONS

This study identified combined anterior and posterior approach and nonuse of iodine-supported spinal instruments to be independent risk factors for SSI after TES. Iodine-supported spinal instrument was extremely effective for prevention of SSI in patients with compromised status, and it had no detection of cytotoxic or adverse effects on the patients.

Для цитирования: Hayashi Hiroyuki, Murakami Hideki, Demura Satoru, Kato Satoshi, Yoshioka Katsuhito, Shinmura Kazuya, Yokogawa Noriaki, Ishii Takayoshi, Fang Xiang, Shirai Toshiharu, Tsuchiya Hiroyuki. Surgical site infection after total en bloc spondylectomy: risk factors and the preventive new technology.. The spine journal : official journal of the North American Spine Society. 2014. DOI: 10.1016/j.spinee.2014.08.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.