MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2017.07.014

Медицинская библиотека · The Journal of hand surgery · 2017

Evaluation of a Nerve Fusion Technique With Polyethylene Glycol in a Delayed Setting After Nerve Injury.

Bamba Ravinder, Riley David Colton, Kim Justine S, Cardwell Nancy L, Pollins Alonda C, Shack R Bruce, Thayer Wesley P

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

PURPOSE: Polyethylene glycol (PEG) has been hypothesized to restore axonal continuity using an in vivo rat sciatic nerve injury model when nerve repair occurs within minutes after nerve injury. We hypothesized that PEG could restore axonal continuity when nerve repair was delayed.

METHODS

The left sciatic nerves of female Sprague-Dawley rats were transected and repaired in an end-to-end fashion using standard microsurgical techniques at 3 time points (1, 8, and 24 hours) after injury. Polyethylene glycol was delivered to the neurorrhaphy in the experimental group. Post-repair compound action potentials were immediately recorded after repair. Animals underwent behavioral assessments at 3 days and 1 week after surgery using the sciatic functional index test. The animals were sacrificed at 1 week to obtain axon counts.

RESULTS

The PEG-treated nerves had improved compound action potential conduction and animals treated with PEG had improved sciatic function index. Compound action potential conduction was restored in PEG-fused rats when nerves were repaired at 1, 8, and 24 hours. In the control groups, no compound action potential conduction was restored when nerves were repaired. Sciatic functional index was superior in PEG-fused rats at 3 and 7 days after surgery compared with control groups at all 3 time points of nerve repair. Distal motor and sensory axon counts were higher in the PEG-treated rats.

CONCLUSIONS

Polyethylene glycol fusion is a new adjunct for nerve repair that allows rapid restoration of axonal continuity. It effective when delayed nerve repair is performed.

CLINICAL RELEVANCE: Nerve repair with application of PEG is a potential therapy that may have efficacy in a clinical setting. It is an experimental therapy that needs more investigation as well as clinical trials.

Для цитирования: Bamba Ravinder, Riley David Colton, Kim Justine S, Cardwell Nancy L, Pollins Alonda C, Shack R Bruce, Thayer Wesley P. Evaluation of a Nerve Fusion Technique With Polyethylene Glycol in a Delayed Setting After Nerve Injury.. The Journal of hand surgery. 2017. DOI: 10.1016/j.jhsa.2017.07.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.