MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02676591231199718

Медицинская библиотека · Perfusion · 2023

Circuit change in neonatal and pediatric extracorporeal membrane oxygenation is associated with adverse outcomes.

Hafezi Niloufar, Markel Troy A, Mark Natalie M, Colgate Cameron L, Shah Supriya, Ninad Nehal, Masso Maldonado Sarina, Gray Brian W

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Extracorporeal membrane oxygenation (ECMO) circuits may be changed during the run for multiple reasons; however, these circuit changes may be associated with adverse events. Predictors for undergoing a circuit change (CC) and their outcomes remain unclear. We hypothesized that neonatal and pediatric CC correlates with increased morbidity and mortality.

METHODS

Pediatric and neonatal patients who underwent one ECMO run lasting <30 days at a tertiary children's hospital from 2011 through 2017 were retrospectively reviewed. Bivariate regression analysis evaluated factors associated with ECMO mortality and morbidity. LASSO logistic regression models identified independent risk factors for undergoing a CC. p < .05 was significant.

RESULTS

One hundred 85 patients were included; 137 (74%) underwent no CC, while 48 (26%) underwent one or more. Undergoing a CC was associated with longer ECMO duration (p < .001), higher blood transfusion volumes (p < .001), increased hemorrhagic complications (p < .001) and increased mortality (p = .002). Increased platelet (p = .001) and FFP (p = .016) transfusion volumes at any time while on ECMO were independent factors associated with undergoing a CC.

CONCLUSIONS

Changing the circuit during the ECMO run occurs frequently and may be associated with poorer outcomes. Understanding the outcomes and predictors for CC may guide management protocols for more efficient circuit changes given its important association with overall outcomes.

Для цитирования: Hafezi Niloufar, Markel Troy A, Mark Natalie M, Colgate Cameron L, Shah Supriya, Ninad Nehal, Masso Maldonado Sarina, Gray Brian W. Circuit change in neonatal and pediatric extracorporeal membrane oxygenation is associated with adverse outcomes.. Perfusion. 2023. DOI: 10.1177/02676591231199718.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.