DOI 10.1016/j.avsg.2013.01.024
Mandibular subluxation as an adjunct in very distal carotid arterial reconstruction: incidence of peripheral and cerebral neurologic sequelae in a single-center experience.
Аннотация
BACKGROUND
The location of the carotid bifurcation and a very distal extension of internal carotid atherosclerotic disease may challenge vascular surgeons performing carotid endarterectomy (CEA) by increasing technical difficulty and possibly the incidence of cranial nerve damage or palsies. The objective of the present study is to report on the safety of CEA with mandibular subluxation (MS) and to compare results of CEA in 2 groups of patients treated by standard CEA or by MS-CEA according to rates of major neurologic complications, death, and the occurrence of postoperative peripheral nerve palsy.
METHODS
Between July 2000 and June 2012, 1,357 CEAs were performed. MS was additionally used in 43 patients. Only patients with primary atherosclerotic internal carotid artery (ICA) lesions in the 2 groups (38 in the MS-CEA group and 1,289 in the standard CEA group) were considered for comparative analysis.
RESULTS
MS-CEA patients were more frequently male (P = 0.03), presented more frequently with symptomatic lesions (P = 0.007), longer lesions (P = 0.01), and had common ICA bypass implantation (P = 0.02). Mean follow-up was 68.75 ± 37.87 months (range: 1-144 months). No perioperative neurologic mortality and no prolonged discomfort related to MS was recorded. The overall neurologic morbidity rate (major stroke/minor stroke/transient ischemic attach) was comparable in the 2 groups (P = 0.78). The overall immediate peripheral nerve injury rate was 7.89% in the MS-CEA group and 5.27% in the standard CEA group (P = 0.73). Three cases of permanent dysphonia in the standard CEA group (0.23%) and 1 case of dysphagia in the MS-CEA group (2.63%) were reported at follow-up (P = 0.24).
CONCLUSIONS
MS-CEA can be a very useful technical adjunct for high-located carotid bifurcations or challenging carotid lesions, with an overall risk comparable to that of standard CEA.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.