DOI 10.1016/j.contraception.2020.08.015
Evaluation of the effect of a new oral contraceptive containing estetrol and drospirenone on hemostasis parameters.
Аннотация
OBJECTIVE
To assess the effect on hemostasis parameters of a new combined oral contraceptive (COC).
STUDY
DESIGN
In this randomized, single centre, open-label, exploratory study, healthy women received either 15 mg estetrol/3 mg drospirenone (E4/DRSP) (n = 39), 30 mcg ethinylestradiol/150 mcg levonorgestrel (EE/LNG) (n = 30), or 20 mcg ethinylestradiol/3 mg drospirenone (EE/DRSP) (n = 32) for six 28-day cycles. Blood was collected at baseline, cycle 3, and cycle 6. Median change from baseline was evaluated for procoagulant, anticoagulant, and fibrinolytic parameters, and for sex hormone-binding globulin (SHBG).
RESULTS
Median change of endogenous thrombin potential (ETP) based activated protein C sensitivity resistance (APCr) at cycle 6 was +30% for E4/DRSP, +165% for EE/LNG (p-value <0.05 vs E4/DRSP), and +219% for EE/DRSP (p-value <0.05 vs E4/DRSP). Changes to prothrombin fragment 1 + 2 and SHBG for E4/DRSP, EE/LNG, and EE/DRSP were +23%, +71%, and +64% (p-value <0.05 vs E4/DRSP); and +55%, +74% and +251% (p-value <0.05 vs E4/DRSP), respectively. At cycle 6, changes to other hemostasis parameters for E4/DRSP were similar or smaller than for EE/LNG or EE/DRSP.
CONCLUSIONS
In this study, changes in hemostasis parameters after treatment with 6 cycles of E4/DRSP were smaller or similar to those observed for EE/LNG. Similar, but more pronounced changes were also observed versus EE/DRSP, which supports the hypothesis that the effect of COCs on hemostasis parameters is mainly mediated by the estrogenic component. Further studies are needed to provide more insight into the venous thromboembolic risk of E4/DRSP.
IMPLICATIONS STATEMENT: This study reports that the effects on hemostasis parameters of a COC containing 15 mg E4/3 mg DRSP are less or similar to those for EE/LNG or EE/DRSP. It also demonstrates that the choice of estrogen modulates the effects of COCs on hemostasis parameters.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.