PURPOSE: We developed a simple method to minimize leg length discrepancy (LLD) during hip arthroplasty. The purpose of this study is to evaluate the accuracy of the method.

PATIENTS AND

METHODS

A total of 47 patients who suffered from unilateral femoral neck fracture and underwent hip hemiarthroplasty between 2015 and 2018 were enrolled in this study. We measured the diameter of the contralateral femoral head (D) and the distance (L) between the center of the femoral head and the top of lesser trochanter in the antero-posterior pelvic X-ray view before the operation, the ratio (R) of D to L was calculated. During the operation, the diameter of the femoral head (d) was measured using a Vernier caliper. Then, the distance should be obtained from the center of the femoral head prosthesis to the lesser trochanter was calculated according to the contralateral ratio R.

RESULTS

The mean LLD was 4.4±3.2 mm (-4.0 to 11.1 mm), 80.9% of the patients had LLD <6 mm, 93.6% of the patients with LLD <10 mm, only 6.4% ≥10 mm LLD.

CONCLUSION

This method is a simple, cost-effective, fast and accurate way to reduce the postoperative leg length discrepancy.

Для цитирования: Wang Guodong, Guo Ai, Yu Fei, Yang Bo, Yu Haomiao, Diao Naicheng, Ma Lifeng, Qiang Hua, Zhao Erhong. A simple method to minimize leg length discrepancy in hip hemiarthroplasty.. Clinical interventions in aging. 2019. DOI: 10.2147/cia.s214935.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.