MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmj.313.7053.329

Медицинская библиотека · BMJ (Clinical research ed.) · 1996

Opening Pandora's box: the unpredictability of reassurance by a normal test result.

McDonald I G, Daly J, Jelinek V M, Panetta F, Gutman J M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To determine the rate of failure of patient reassurance after a normal test result and study the determinants of failure.

DESIGN

Replicated single case study with qualitative and quantitative data analysis.

SETTING

University teaching hospital.

SUBJECTS: 40 consecutive patients referred for echocardiography either because of symptoms (10 patients) or because of a heart murmur (30). 39 were shown to have a normal heart.

INTERVENTIONS: Medical consultations and semistructured patient interviews were tape recorded. Structured interviews with consultant cardiologists were recorded in survey form.

MAIN OUTCOME MEASURES: Patient recall of the explanation and residual understanding, doubt, and anxiety about the heart after the test and post-test consultation.

RESULTS

All 10 patients presenting with symptoms were left with anxiety about the heart despite a normal test result and reassurance by the consultant. Of 28 patients referred because of a murmur but shown to have no heart abnormality, 20 became anxious after detection of the murmur; 11 had residual anxiety despite the normal test result.

CONCLUSIONS

Reassurance of the "worried well"-anxious patients with symptoms or patients concerned by a health query resulting from a routine medical examination or from screening-constitutes a large part of medical practice. It seems to be widely assumed that explaining that tests have shown no abnormality is enough to reassure. The results of this study refute this and emphasise the importance of personal and social factors as obstacles to reassurance.

Для цитирования: McDonald I G, Daly J, Jelinek V M, Panetta F, Gutman J M. Opening Pandora's box: the unpredictability of reassurance by a normal test result.. BMJ (Clinical research ed.). 1996. DOI: 10.1136/bmj.313.7053.329.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.