Preliminary in vivo breast vibro-acoustography results with a quasi-2-d array transducer: a step forward.

Mehrmohammadi Mohammad, Fazzio Robert T, Whaley Dana H, Pruthi Sandhya, Kinnick Randall R, Fatemi Mostafa, Alizad Azra

Клинический случайСтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

We previously investigated the application of a novel imaging modality, vibro-acoustography (VA), using an annular confocal transducer (confocal VA) integrated into a clinical prone stereotactic mammography system, to detect various breast abnormalities. To shorten the scanning time and provide improved coverage of the breast, we have evolved our imaging system by implementing VA on a clinical ultrasound scanner equipped with a ‘‘quasi-2-D’’ array transducer. We call this technique ‘‘quasi-2-D vibro-acoustography’’ (Q2-DVA). A clinical ultrasound scanner (GE Vivid 7) was modified to perform both ultrasound imaging and VAusing an array transducer consisting of a matrix of 12 rows by 70 columns of ultrasound elements. The newly designed system was used to perform VA on patients with either benign or cancerous lesions. Our results indicate that benign and malignant solid breast lesions were easily detected using our newly modified VA system. It was also possible to detect microcalcifications within the breast. Our results suggest that with further development, Q2-DVA could provide high-resolution diagnostic information in the clinical setting and may be used either as a stand-alone or as a complementary tool in support of other clinical imaging modalities.

Для цитирования: Mehrmohammadi Mohammad, Fazzio Robert T, Whaley Dana H, Pruthi Sandhya, Kinnick Randall R, Fatemi Mostafa, Alizad Azra. Preliminary in vivo breast vibro-acoustography results with a quasi-2-d array transducer: a step forward.. Ultrasound in medicine & biology. 2014. DOI: 10.1016/j.ultrasmedbio.2014.07.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.