Аннотация

OBJECTIVE

The purpose of the study was to evaluate the safety and feasibility of treatment for male circumcision using modified sleeve circumcision and subcuticular suture with the Quill™ device.

METHODS

From May 2011 to March 2012, 70 consecutive cases of male circumcision were performed using an alternative technique with the Quill™ device by a single surgeon in our institution. The inclusion and exclusion criteria for the selection process of this procedure were the same as for conventional circumcision. We evaluated the indications and perioperative outcomes. The circumcisions were performed as day-case procedures under local anesthesia.

RESULTS

All patients were followed up for a minimum of 3-6 months. The ages ranged from 8 to 68 (mean = 27.0 years, SD = 10). The indications for surgery were either cosmetic (n = 16, 22.9%) or medical [redundant prepuce (n = 36, 51.4%), phimosis (n = 5, 7.1%), paraphimosis (n = 2, 2.9%), balanoposthitis (n = 9, 12.9%), melanoma (n = 1, 1.4%), and condyloma acuminata (n = 1, 1.4%)] (n = 54, 77.1%). The mean operation time in this group was 29 min (19-38 min) when the Quill™ device was used. In all, 3 cases developed complications (4.3%). The final cosmetic result was satisfactory for both the patients and their spouses or parents.

CONCLUSION

This study showed that modified sleeve circumcision and subcuticular suture were safe and reliable surgical methods of circumcision that provide a better cosmetic result.

Для цитирования: Gu Chaohui, Tian Fengyan, Jia Zhankui, Li Guanru, Meng Zhenglei, Xing Weizhi, Ding Yafei, Jin Zhibo, Kan Quancheng, Yang Jinjian. Introducing the Quill™ device for modified sleeve circumcision with subcutaneous suture: a retrospective study of 70 cases.. Urologia internationalis. 2015. DOI: 10.1159/000368660.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.