MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2026.467152

Медицинская библиотека · Journal of chromatography. A · 2026

High correlation of HPSEC-MALLS-based viral particle quantification to infectivity enables quality-by-design for recombinant vesicular stomatitis virus process development.

Li Zhengjun, Jia Xinyu, Xie Boyu, Zhao Jingyang, Ma Yanyan, Su Zhiguo, Zhang Songping

СтатьяПеревод в очереди

Аннотация

Traditional viral titer methods (e.g., TCID₅₀) are activity-based and time-consuming, limiting rapid process development and quality by design (QbD) for viral vector production. Here, using recombinant vesicular stomatitis virus (rVSV) as a model, we established a method based on high performance size exclusion chromatography coupled with multi angle laser light scattering (HPSEC -MALLS) to simultaneously monitor viral particle concentration and purity. Importantly, the physical particle concentration measured by HPSEC-MALLS correlated strongly with biological infectivity (TCID₅₀), yielding an R² of 0.975. Leveraging this correlation, we achieved real-time quality control across downstream and upstream processes. During the upstream culture stage, a multiplicity of infection (MOI) of 0.1 maximized particle production. For purification, Capto Core 700 multimodal chromatography achieved 83.53% particle recovery while removing >99% of host cell proteins and nucleic acids. In formulation studies, sucrose preserved 95.20% particle stability after five weeks at 4 °C, whereas trehalose yielded 94.92% retention following lyophilization. This HPSEC-MALLS platform enables rapid, label-free, multi parameter quality control throughout the entire viral vector process, accelerating both process optimization and clinical translation.

Для цитирования: Li Zhengjun, Jia Xinyu, Xie Boyu, Zhao Jingyang, Ma Yanyan, Su Zhiguo, Zhang Songping. High correlation of HPSEC-MALLS-based viral particle quantification to infectivity enables quality-by-design for recombinant vesicular stomatitis virus process development.. Journal of chromatography. A. 2026. DOI: 10.1016/j.chroma.2026.467152.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.