MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2319/010414-13.1

Медицинская библиотека · The Angle orthodontist · 2014

Asymmetric severe skeletal Class II division 1 patient with temporomandibular joint disorder treated with zygomatic anchorage devices and Ni-Ti alloy wires.

Ishida Takayoshi, Ono Takashi

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To describe the orthodontic treatment of a nongrowing 30-year-old woman with asymmetric severe skeletal Class II malocclusions (asymmetric Angle Class II), large overjet (16 mm), large overbite (8 mm), two congenitally missing mandibular incisors (presenting a deciduous anterior tooth), and signs and symptoms of temporomandibular joint disorder (TMD).

MATERIALS AND

METHODS

We used novel improved super-elastic Ni-Ti alloy wires (ISWs) combined with Ni-Ti alloy coil springs, power hooks, and a zygomatic implant as reinforced anchorage to provide a constant and continuous mild force to the dentition.

RESULTS

We successfully distalized maxillary molars, premolars, and retracted anterior teeth and corrected the asymmetric Angle Class II molar relationship using this system of zygomatic anchorage in conjunction with ISWs, Ni-Ti alloy open-coil springs, and crimpable power hook. The maxillary molars were distalized, and postero-occlusal relationships were improved to achieve Class I canine and molar relationships on both sides. Intrusion of the upper molars made the mandibular plane close. Ideal overbite and overjet relationships were established. Facial esthetics were improved with decreased upper and lower lip protrusion, and no symptoms of TMD were observed after treatment.

CONCLUSION

The orthodontic treatment described here is a promising anchorage technique alternative to traditional techniques to improve severe skeletal Class II with TMD.

Для цитирования: Ishida Takayoshi, Ono Takashi. Asymmetric severe skeletal Class II division 1 patient with temporomandibular joint disorder treated with zygomatic anchorage devices and Ni-Ti alloy wires.. The Angle orthodontist. 2014. DOI: 10.2319/010414-13.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.