MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acvd.2019.11.004

Медицинская библиотека · Archives of cardiovascular diseases · 2020

Transcatheter closure of a perimembranous ventricular septal defect with Nit-Occlud Lê VSD Coil: A French multicentre study.

Houeijeh Ali, Godart François, Jalal Zakaria, Ovaert Caroline, Heitz François, Mauran Pierre, Baruteau Alban-Elouen, Guirguis Lisa, Hadeed Khaled, Baudelet Jean-Benoit, Iriart Xavier, Aldebert Philippe, Acar Philippe, Fraisse Alain, Odemis Ender, Karsenty Clément, Thambo Jean Benoit, Hascoët Sébastien

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Transcatheter perimembranous ventricular septal defect (pmVSD) closure remains challenging and is seldom used in France given the risk of atrioventricular block (AVB). pmVSD closure with the Nit-Occlud Lê VSD coil was recently introduced in France as an alternative to occluder devices.

AIMS: To study the safety and feasibility of pmVSD closure with the Nit-Occlud Lê VSD coil.

METHODS

All consecutives cases of pmVSD closure with the Nit-Occlud Lê VSD coil in 20 tertiary French centres were included between January 2015 and December 2018.

RESULTS

Among 46 procedures in five centres, indications for pmVSD closure were left ventricle overload (76.1%), exertional dyspnoea (17.4%), history of infective endocarditis (4.3%) and mild pulmonary hypertension (2.2%). The median (interquartile [IQR]) age of the patients was 13.9 (5.7-31.8) years. Aneurismal tissue was identified in 91.3% of patients. VSD median (IQR) size was 8 (7-10) mm on the left ventricle side and 5 (4-6) mm on the right ventricle side. Implantation was successful in 40 patients (87.0%; 95% confidence interval [CI] 73.7-95.1%). Severe complications occurred in six patients (13.0%, 95% CI 4.9-26.3%), mainly severe haemolysis (8.7%, 95% CI 2.4-20.8%). One aortic valve lesion required surgical aortic valvuloplasty. Occurrence of severe complications was significantly related to the presence of haemolysis (P=0.001), residual shunt (P=0.007) and multi-exit VSD (P=0.005). Residual shunt was observed in 40% of cases with the implanted device shortly after closure and 15% after a median follow-up of 27 months. No immediate or delayed device embolization or complete AVB was recorded.

CONCLUSION

pmVSD closure with the Nit-Occlud Lê VSD Coil is feasible in older children and adults. However, residual shunting (leading to haemolysis) is a dreaded complication that should not be tolerated. pmVSD closure with the Nit-Occlud Lê VSD as a therapeutic strategy remains controversial and is limited to selected patients.

Для цитирования: Houeijeh Ali, Godart François, Jalal Zakaria, Ovaert Caroline, Heitz François, Mauran Pierre, Baruteau Alban-Elouen, Guirguis Lisa, Hadeed Khaled, Baudelet Jean-Benoit, Iriart Xavier, Aldebert Philippe, Acar Philippe, Fraisse Alain, Odemis Ender, Karsenty Clément, Thambo Jean Benoit, Hascoët Sébastien. Transcatheter closure of a perimembranous ventricular septal defect with Nit-Occlud Lê VSD Coil: A French multicentre study.. Archives of cardiovascular diseases. 2020. DOI: 10.1016/j.acvd.2019.11.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.