MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/sleep/zsy262

Медицинская библиотека · Sleep · 2019

Relationship of stroke volume to different patterns of Cheyne-Stokes respiration in heart failure.

Inami Toru, Kasai Takatoshi, Yumino Dai, Perger Elisa, Alshaer Hisham, Hummel Richard, Lyons Owen D, Floras John S, Bradley T Douglas

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

OBJECTIVES

In patients with heart failure (HF) and reduced left ventricular ejection fraction (HFrEF), stroke volume (SV) falls during hyperpnea of Cheyne-Stokes respiration with central sleep apnea (CSR-CSA). We have identified two distinct patterns of hyperpnea: positive, in which end-expiratory lung volume (EELV) remains at or above functional residual capacity (FRC), and negative, in which EELV falls below FRC. The increase in expiratory intrathoracic pressure generated by the latter should have effects on the heart analogous to external chest compression. To test the hypotheses that in HFrEF patients, CSR-CSA with the negative pattern has an auto-resuscitation effect such that compared with the positive pattern, it is associated with a smaller fall in SV and a smaller increase in cardiac workload (product of heart rate and systolic blood pressure).

METHODS

In 15 consecutive HFrEF patients with CSR-CSA during polysomnography, hemodynamic data derived from digital photoplethysmography during positive and negative hyperpneas were compared.

RESULTS

Compared to the positive, negative hyperpneas were accompanied by reductions in the maximum and mean relative fall in SV of 30% (p = 0.002) and 10% (p = 0.031), respectively, and by reductions in the degree of increases in heart rate and rate pressure product during hyperpnea of 46% (p < 0.001) and 13% (p = 0.007), respectively.

CONCLUSIONS

Our findings suggest the novel concept that the negative pattern of CSR-CSA may constitute a form of auto-resuscitation that acts as a compensatory mechanism to maintain SV in patients with severe HF.

Для цитирования: Inami Toru, Kasai Takatoshi, Yumino Dai, Perger Elisa, Alshaer Hisham, Hummel Richard, Lyons Owen D, Floras John S, Bradley T Douglas. Relationship of stroke volume to different patterns of Cheyne-Stokes respiration in heart failure.. Sleep. 2019. DOI: 10.1093/sleep/zsy262.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.