Haddad Raymond N, Daou Linda S, Saliba Zakhia S
Аннотация
OBJECTIVES: To evaluate the safety, efficiency, and midterm outcomes of transcatheter perimembranous ventricular septal defect (pmVSD) closure using the new KONAR-MF™ VSD occluder.
BACKGROUND: Off-label percutaneous pmVSD closure is a well-established procedure with promising results. Yet, interventionists are still searching for the ideal device.
METHODS: Between June 2018 and March 2019, 20 patients with hemodynamically significant but restrictive-type pmVSD underwent an attempted transcatheter closure using the new KONAR-MF™. All implantations were performed retrogradely under general anesthesia, transoesophageal echocardiography, and fluoroscopic guidance. Prospective follow-up using transthoracic echocardiography and electrocardiogram was done until August 2019.
RESULTS: The median age was 6.4 years (8 months to 43.4 years), and the median body weight was 17.3 (9-74) kg. The mean defect size on the left ventricular aspect was 11.7 ± 2.8 mm. All devices were successfully and rapidly implanted. One device embolized in the pulmonary artery, 24 hr after implantation and was percutaneously retrieved with no complication. Over a mean follow-up period of 8.2 ± 3.0 months, complete closure was achieved in 84.2% of patients. One new onset of mild aortic regurgitation was detected before discharge and remained stable. Tricuspid valve regurgitation, complete heart block, major complication, and death were not observed.
CONCLUSIONS: Transcatheter pmVSD closure using the KONAR-MF™ can be successfully performed in adult and pediatric patients. It is a safe and promising device, designed to provide high conformability to septal defects with a lower risk of heart block. Retrograde implantation allows procedural flexibility, efficient deliverability, and control of valvular interferences.
BACKGROUND: Off-label percutaneous pmVSD closure is a well-established procedure with promising results. Yet, interventionists are still searching for the ideal device.
METHODS: Between June 2018 and March 2019, 20 patients with hemodynamically significant but restrictive-type pmVSD underwent an attempted transcatheter closure using the new KONAR-MF™. All implantations were performed retrogradely under general anesthesia, transoesophageal echocardiography, and fluoroscopic guidance. Prospective follow-up using transthoracic echocardiography and electrocardiogram was done until August 2019.
RESULTS: The median age was 6.4 years (8 months to 43.4 years), and the median body weight was 17.3 (9-74) kg. The mean defect size on the left ventricular aspect was 11.7 ± 2.8 mm. All devices were successfully and rapidly implanted. One device embolized in the pulmonary artery, 24 hr after implantation and was percutaneously retrieved with no complication. Over a mean follow-up period of 8.2 ± 3.0 months, complete closure was achieved in 84.2% of patients. One new onset of mild aortic regurgitation was detected before discharge and remained stable. Tricuspid valve regurgitation, complete heart block, major complication, and death were not observed.
CONCLUSIONS: Transcatheter pmVSD closure using the KONAR-MF™ can be successfully performed in adult and pediatric patients. It is a safe and promising device, designed to provide high conformability to septal defects with a lower risk of heart block. Retrograde implantation allows procedural flexibility, efficient deliverability, and control of valvular interferences.