MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.28678

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019

Percutaneous closure of restrictive-type perimembranous ventricular septal defect using the new KONAR multifunctional occluder: Midterm outcomes of the first middle-eastern experience.

Haddad Raymond N, Daou Linda S, Saliba Zakhia S

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the safety, efficiency, and midterm outcomes of transcatheter perimembranous ventricular septal defect (pmVSD) closure using the new KONAR-MF™ VSD occluder.

BACKGROUND

Off-label percutaneous pmVSD closure is a well-established procedure with promising results. Yet, interventionists are still searching for the ideal device.

METHODS

Between June 2018 and March 2019, 20 patients with hemodynamically significant but restrictive-type pmVSD underwent an attempted transcatheter closure using the new KONAR-MF™. All implantations were performed retrogradely under general anesthesia, transoesophageal echocardiography, and fluoroscopic guidance. Prospective follow-up using transthoracic echocardiography and electrocardiogram was done until August 2019.

RESULTS

The median age was 6.4 years (8 months to 43.4 years), and the median body weight was 17.3 (9-74) kg. The mean defect size on the left ventricular aspect was 11.7 ± 2.8 mm. All devices were successfully and rapidly implanted. One device embolized in the pulmonary artery, 24 hr after implantation and was percutaneously retrieved with no complication. Over a mean follow-up period of 8.2 ± 3.0 months, complete closure was achieved in 84.2% of patients. One new onset of mild aortic regurgitation was detected before discharge and remained stable. Tricuspid valve regurgitation, complete heart block, major complication, and death were not observed.

CONCLUSIONS

Transcatheter pmVSD closure using the KONAR-MF™ can be successfully performed in adult and pediatric patients. It is a safe and promising device, designed to provide high conformability to septal defects with a lower risk of heart block. Retrograde implantation allows procedural flexibility, efficient deliverability, and control of valvular interferences.

Для цитирования: Haddad Raymond N, Daou Linda S, Saliba Zakhia S. Percutaneous closure of restrictive-type perimembranous ventricular septal defect using the new KONAR multifunctional occluder: Midterm outcomes of the first middle-eastern experience.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2019. DOI: 10.1002/ccd.28678.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.