Extracorporeal life support without systemic anticoagulation: a nitric oxide-based non-thrombogenic circuit for the artificial placenta in an ovine model.

Fallon Brian P, Lautner-Csorba Orsolya, Major Terry C, Lautner Gergely, Harvey Stephen L, Langley Mark W, Johnson Matthew D, Saveski Claudia, Matusko Niki, Rabah Raja, Rojas-Pena Alvaro, Meyerhoff Mark E, Bartlett Robert H, Mychaliska George B

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Clinical translation of the extracorporeal artificial placenta (AP) is impeded by the high risk for intracranial hemorrhage in extremely premature newborns. The Nitric Oxide Surface Anticoagulation (NOSA) system is a novel non-thrombogenic extracorporeal circuit. This study aims to test the NOSA system in the AP without systemic anticoagulation.

METHODS

Ten extremely premature lambs were delivered and connected to the AP. For the NOSA group, the circuit was coated with DBHD-N2O2/argatroban, 100 ppm nitric oxide was blended into the sweep gas, and no systemic anticoagulation was given. For the Heparin control group, a non-coated circuit was used and systemic anticoagulation was administered.

RESULTS

Animals survived 6.8 ± 0.6 days with normal hemodynamics and gas exchange. Neither group had any hemorrhagic or thrombotic complications. ACT (194 ± 53 vs. 261 ± 86 s; p < 0.001) and aPTT (39 ± 7 vs. 69 ± 23 s; p < 0.001) were significantly lower in the NOSA group than the Heparin group. Platelet and leukocyte activation did not differ significantly from baseline in the NOSA group. Methemoglobin was 3.2 ± 1.1% in the NOSA group compared to 1.6 ± 0.6% in the Heparin group (p < 0.001).

CONCLUSIONS

The AP with the NOSA system successfully supported extremely premature lambs for 7 days without significant bleeding or thrombosis.

IMPACT: The Nitric Oxide Surface Anticoagulation (NOSA) system provides effective circuit-based anticoagulation in a fetal sheep model of the extracorporeal artificial placenta (AP) for 7 days. The NOSA system is the first non-thrombogenic circuit to consistently obviate the need for systemic anticoagulation in an extracorporeal circuit for up to 7 days. The NOSA system may allow the AP to be implemented clinically without systemic anticoagulation, thus greatly reducing the intracranial hemorrhage risk for extremely low gestational age newborns. The NOSA system could potentially be applied to any form of extracorporeal life support to reduce or avoid systemic anticoagulation.

Для цитирования: Fallon Brian P, Lautner-Csorba Orsolya, Major Terry C, Lautner Gergely, Harvey Stephen L, Langley Mark W, Johnson Matthew D, Saveski Claudia, Matusko Niki, Rabah Raja, Rojas-Pena Alvaro, Meyerhoff Mark E, Bartlett Robert H, Mychaliska George B. Extracorporeal life support without systemic anticoagulation: a nitric oxide-based non-thrombogenic circuit for the artificial placenta in an ovine model.. Pediatric research. 2023. DOI: 10.1038/s41390-023-02605-2.