MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10072-025-08102-0

Медицинская библиотека · Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2025

Deep brain stimulation in Parkinson's disease: a comparison of accuracy and clinical outcomes of frame-based, frameless and frameless fiducial-less techniques.

Ricciuti Riccardo Antonio, Ottaviani Matteo Maria, Mancini Fabrizio, Marano Massimo, Marruzzo Daniele, Barbieri Francesca, Paracino Riccardo, De Domenico Pierfrancesco, Pagano Serena, Di Lazzaro Vincenzo, Dobran Mauro

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The effectiveness of deep brain stimulation (DBS) for Parkinson's disease (PD) depends on implantation accuracy. DBS initially employed a stereotactic frame (frame-based, FB), but technological advancements led to the development of less invasive methods based on fiducial markers (F + F) or intraoperative imaging (F-F). This study compares the accuracy and efficacy of three DBS-STN implantation techniques.

METHODS

This retrospective study involved 18 patients with PD who underwent bilateral STN DBS between 2018 and 2023. Patients were divided into three groups: FB (n = 6), F + F (n = 7), and F-F (n = 5). Postoperative CT and preoperative MRI fusion were used to evaluate electrode accuracy via deviations from planned targets in x, y, z axes, and calculate the radial error (RE) and vector error (VE). We analyzed Unified Parkinson's Disease Rating Scale (UPDRS) III scores in four "on/off medication-stimulation" combinations, LEDD, and disease stage before DBS, and 3 and 12 months post-DBS.

RESULTS

No statistically significant differences were observed between the three methods in|Δx| (FB = 1.30 ± 0.91; F + F = 1.05 ± 0.93; F-F = 1.33 ± 1.09 mm),|Δy| (FB = 0.95 ± 0.98; F + F = 1.11 ± 1.17; F-F = 1.28 ± 1.14 mm), RE (FB = 1.82 ± 0.29; F + F = 1,71 ± 0,36; F-F = 1,91 ± 1,49 mm) and VE (FB = 3,14 ± 0,35 mm; F + F = 4,92 ± 0,54 mm; F-F = 4,42 ± 1,22 mm). All groups demonstrated significant UPDRS III (> 50%) and LEDD reduction (> 40%) at 12 months, with no intergroup differences.

CONCLUSIONS

The study concludes that all three techniques provide equivalent accuracy and clinical efficacy. Centers should select DBS-STN methods based on available resources and expertise.

Для цитирования: Ricciuti Riccardo Antonio, Ottaviani Matteo Maria, Mancini Fabrizio, Marano Massimo, Marruzzo Daniele, Barbieri Francesca, Paracino Riccardo, De Domenico Pierfrancesco, Pagano Serena, Di Lazzaro Vincenzo, Dobran Mauro. Deep brain stimulation in Parkinson's disease: a comparison of accuracy and clinical outcomes of frame-based, frameless and frameless fiducial-less techniques.. Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology. 2025. DOI: 10.1007/s10072-025-08102-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.