MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1532-950x.2006.00170.x

Медицинская библиотека · Veterinary surgery : VS · 2006

A clinical evaluation of a headless, titanium, variable-pitched, tapered, compression screw for repair of nondisplaced lateral condylar fractures in thoroughbred racehorses.

Galuppo Larry D, Simpson Edwin L, Greenman Sylvia L, Dowd Joseph P, Ferraro Gregory L, Meagher Dennis M

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To report clinical evaluation of headless compression screws for repair of metacarpal/metatarsal (MC/MT3) condylar fractures in horses.

STUDY

DESIGN

Retrospective case study.

SAMPLE POPULATION: Racing Thoroughbreds (n=16) with nondisplaced lateral condylar fractures of MC/MT 3.

METHODS

Medical records (1999-2004) of horses with nondisplaced longitudinal fractures of the lateral condyle of MC/MT3 were reviewed. Pre-operative variables retrieved were: patient age, gender, limb involvement, injury occurrence, fracture length, and width, evidence of palmar comminution and degenerative joint disease, number of pre-injury starts, and pre-injury earnings. Post-operative variables retrieved were: surgical complications, surgical time, number of race starts, and post-operative earnings.

RESULTS

MC3 (n=11) and MT3 (5) nondisplaced longitudinal fractures of the lateral condyle were repaired with Acutrak Equine (AE) screws. Left front limb fractures were most common (8) followed by left hind (5) and right front (3). Nine fractures occurred during training and 7 during racing; 4 fractures had palmar comminution. No surgical complications occurred. Of 15 horses that returned to training, 11 (73%) raced 306+/-67 days after injury and had greater mean (+/-SD) post-injury earnings/start ($5290.00+/-$8124.00) than pre-injury ($4971.00+/-$2842.00). Screw removal was not required in any horse.

CONCLUSION

The AE screw is a viable option for repair of nondisplaced lateral condylar MC/MT3 fractures in Thoroughbred racehorses.

CLINICAL RELEVANCE: Adequate stability of nondisplaced lateral condylar fractures can be achieved with a headless tapered compression screw while avoiding impingement on the collateral ligaments and joint capsule of the fetlock joint.

Для цитирования: Galuppo Larry D, Simpson Edwin L, Greenman Sylvia L, Dowd Joseph P, Ferraro Gregory L, Meagher Dennis M. A clinical evaluation of a headless, titanium, variable-pitched, tapered, compression screw for repair of nondisplaced lateral condylar fractures in thoroughbred racehorses.. Veterinary surgery : VS. 2006. DOI: 10.1111/j.1532-950x.2006.00170.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.