Fetal diagnosis and therapy · 2001
Fetomaternal transfusion and pregnancy outcome after cordocentesis.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sikovanyecz J, Horváth E, Sallay E, Gellén J, Pál A, Szabó J
Аннотация
OBJECTIVE: To study the extent of fetomaternal transfusion and the outcome of pregnancy after cordocentesis.
MATERIAL AND METHODS: 268 women underwent percutaneous fetal umbilical cord blood sampling for fetal karyotyping between 15 and 26 gestations of weeks. Complete follow-up was available in 221 (82.5%) of the cases. Cordocentesis was performed under continuous real-time ultrasound guidance. The duration of the procedure and the post-procedural bleeding time was counted in seconds. Fetomaternal transfusion was calculated by using the measurements of the maternal serum levels of alpha-fetoprotein before and after the procedure. The data were analyzed by Student's t and multiple regression tests.
RESULTS: The maximum and mean amounts of fetomaternal transfusion were 1.067 and 0.061 ml, respectively. Twenty percent or more alpha-fetoprotein elevation was in 35.4% of the cases. Positive correlation was found between bleeding time after cordocentesis and fetomaternal transfusion (r = 0.174, p < 0.0129) as well as between the duration of the procedure (r = 0.165, p < 0.0171) and the amount of fetomaternal transfusion. Comparing the cordocentesis at the placental insertion site and at the free cord loop, a smaller amount of fetomaternal transfusion was observed (p < 0.0123) in the latter. Transplacental passage was associated with a higher amount of fetomaternal transfusion (p < 0.0067). No association was found between the extent of fetomaternal transfusion and the outcome of pregnancy. The fetal loss related to the cordocentesis was 0.50%.
CONCLUSIONS: The extent of fetomaternal transfusion was influenced by the subsequent four parameters: procedural time, bleeding time, puncture site and transplacental penetration. The lack of the association between the degree of fetomaternal transfusion and the outcome of pregnancy, along with the low (0.50%) post-procedural fetal loss rate, suggest that cordocentesis is clinically a safe procedure.
MATERIAL AND METHODS: 268 women underwent percutaneous fetal umbilical cord blood sampling for fetal karyotyping between 15 and 26 gestations of weeks. Complete follow-up was available in 221 (82.5%) of the cases. Cordocentesis was performed under continuous real-time ultrasound guidance. The duration of the procedure and the post-procedural bleeding time was counted in seconds. Fetomaternal transfusion was calculated by using the measurements of the maternal serum levels of alpha-fetoprotein before and after the procedure. The data were analyzed by Student's t and multiple regression tests.
RESULTS: The maximum and mean amounts of fetomaternal transfusion were 1.067 and 0.061 ml, respectively. Twenty percent or more alpha-fetoprotein elevation was in 35.4% of the cases. Positive correlation was found between bleeding time after cordocentesis and fetomaternal transfusion (r = 0.174, p < 0.0129) as well as between the duration of the procedure (r = 0.165, p < 0.0171) and the amount of fetomaternal transfusion. Comparing the cordocentesis at the placental insertion site and at the free cord loop, a smaller amount of fetomaternal transfusion was observed (p < 0.0123) in the latter. Transplacental passage was associated with a higher amount of fetomaternal transfusion (p < 0.0067). No association was found between the extent of fetomaternal transfusion and the outcome of pregnancy. The fetal loss related to the cordocentesis was 0.50%.
CONCLUSIONS: The extent of fetomaternal transfusion was influenced by the subsequent four parameters: procedural time, bleeding time, puncture site and transplacental penetration. The lack of the association between the degree of fetomaternal transfusion and the outcome of pregnancy, along with the low (0.50%) post-procedural fetal loss rate, suggest that cordocentesis is clinically a safe procedure.