MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2006.04.005

Медицинская библиотека · The Journal of hand surgery · 2006

Correction of malunited intra-articular distal radius fractures with an inside-out osteotomy technique.

del Piñal Francisco, García-Bernal Francisco J, Delgado Julio, Sanmartín Marcos, Regalado Javier, Cerezal Luis

СтатьяПеревод в очереди

Аннотация

PURPOSE: To present an inside-out osteotomy technique under arthroscopic guidance to correct an intra-articular malunion.

METHODS

The joint is explored with a 2.7-mm arthroscope through the standard portals without infusing any water. To allow room to introduce the curettes and the osteotomes (4-mm wide), the instrumentation portals are made slightly larger than usual. Malunited fragments are cut with the osteotomes from inside the joint and advanced out. Fragments are mobilized, and granulating tissue and/or new bone is removed with curettes and synoviotomes. After disimpaction and reduction, fixation with plates or screws via the appropriate open approach is performed under arthroscopic control. No water is used throughout the procedure except at the end of the surgery to clear out debris.

RESULTS

Steps were corrected to 0 mm in all patients. Gaps of less than 1 mm were common.

CONCLUSIONS

This procedure allows us to define each cartilage-containing fragment and to re-create the original articular fracture line without the fear of creating new fracture lines on the articular surface. This technique can be used for patients with irregularly defined fragments that are not amenable to classic techniques. The key to the procedure is to perform the arthroscopic exploration without water infusion (dry technique).

Для цитирования: del Piñal Francisco, García-Bernal Francisco J, Delgado Julio, Sanmartín Marcos, Regalado Javier, Cerezal Luis. Correction of malunited intra-articular distal radius fractures with an inside-out osteotomy technique.. The Journal of hand surgery. 2006. DOI: 10.1016/j.jhsa.2006.04.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.