In vitro comparison of linear vs triangular screw configuration to stabilize complete uniarticular parasagittal fractures of the proximal phalanx in horses.

Labens Raphael, Khairuddin Nurul H, Murray Mark, Jermyn Kieri, Ahmad Roohi S

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess fracture gap reduction and stability of linear vs triangular 4.5-mm lag screw repair of experimental, uniarticular, and complete forelimb proximal phalanx (P1) fractures.

STUDY

DESIGN

Experimental.

SAMPLE POPULATION: Fourteen equine cadaver limbs/horses.

METHODS

Simulated fractures were repaired with 2 lag screws under 4-Nm insertion torque (linear repair). Computed tomography (CT) imaging was performed with the leg unloaded and loaded to forces generated while walking. The fracture repair was revised to include 3 lag screws placed with the same insertion torque (triangular repair) prior to CT. The width of the fracture gap was assessed qualitatively by 2 observers and graded on the basis of gap measurements relative to the average voxel size at dorsal, mid, and palmar P1 sites. Interobserver agreement was assessed with Cohen's κ. The effect of repair type, loading condition, and measurement site on fracture gap grades was evaluated by using Kendall's τ-b correlation coefficients and paired nonparametric tests. Significance was set at P ≤ .05.

RESULTS

Agreement between loading and fracture gap widening was fair in triangular (κ = 0.53) and excellent in linear (κ = 0.81) repairs. Loading resulted in fracture gap distraction in linear repairs (Plinear  = .008). Triangular repairs reduced fractures better irrespective of loading (Punloaded  = .003; Ploaded  < .001). The type of repair was not correlated with fracture gap grades at unloaded mid and loaded dorsal P1 sites.

CONCLUSION

Repair of uniarticular complete parasagittal fractures with a triangular screw configuration improved in vitro fracture gap reduction and stability.

CLINICAL SIGNIFICANCE: Triangular lag screw repair likely improves biomechanical conditions during postoperative weight bearing.

Для цитирования: Labens Raphael, Khairuddin Nurul H, Murray Mark, Jermyn Kieri, Ahmad Roohi S. In vitro comparison of linear vs triangular screw configuration to stabilize complete uniarticular parasagittal fractures of the proximal phalanx in horses.. Veterinary surgery : VS. 2018. DOI: 10.1111/vsu.13123.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.