MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.124.013237

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2025

Validation of a Demography-Based Adaptive QT Correction Formula Using Pediatric and Adult Datasets Acquired From Humans and Guinea Pigs.

Haq Kazi T, McLean Kate M, Anderson-Barker Grace C, Berul Charles I, Shattock Michael J, Posnack Nikki Gillum

СтатьяВалидационное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

QT correction (QTc) formulae are widely used in clinical and research settings but often underperform, possibly due to demographic influences on the QT-heart rate (HR) relationship. To address this limitation, we developed an adaptive QTc (QTcAd) formula, which adjusts for demographic factors like age, and compared its efficacy to other standard formulae.

METHODS

The QTcAd formula was tested across diverse age groups with different HR in both humans and guinea pigs. Using retrospective ECG data from 1819 pediatric patients at Children's National Hospital and 2400 subjects from the Pediatric Heart Network database, alongside in vivo (N=55) and ex vivo (N=66) guinea pig ECG recordings, we evaluated the formula's effectiveness. Linear regression fit parameters of QTc-HR (slope and R²) were utilized for performance assessment. To evaluate the accuracy of the predicted QTc, we acquired epicardial electrical and optical voltage data from Langendorff-perfused guinea pig hearts.

RESULTS

In both human subjects and guinea pigs, the QTcAd formula (QTcAd=QT+(|m|×(HR-HRmean)) consistently outperformed other formulae across all age groups. For instance, in a 20-year-old human group, the QTcAd formula successfully nullified the inverse QT-HR relationship (R²=5.1×10-10, slope=-3.5×10-5), whereas the Bazett formula failed to achieve comparable effectiveness (R²=0.21, slope=0.91). Moreover, the QTcAd formula exhibited better accuracy than the age-specific Benatar QTc formula, which overcorrected QTc (1-week human QT: 263.8±14.8 ms, QTcAd: 263.8±7.3 ms, P=0.62; Benatar QTc: 422.5±7.3 ms, P<0.0001). The optically measured pseudo-QT interval (143±22.5 ms, n=44) was better approximated by QTcAd (180.6±17.0 ms) compared with all other formulae. Furthermore, we demonstrated that the QTcAd formula was not inferior to individual-specific QTc formulae.

CONCLUSIONS

The demography-based QTcAd formula showed superior performance across human and guinea pig age groups, which may enhance the efficacy of rate-corrected K.M.M. for cardiovascular disease diagnosis, risk stratification, and drug safety testing in children and adults.

Для цитирования: Haq Kazi T, McLean Kate M, Anderson-Barker Grace C, Berul Charles I, Shattock Michael J, Posnack Nikki Gillum. Validation of a Demography-Based Adaptive QT Correction Formula Using Pediatric and Adult Datasets Acquired From Humans and Guinea Pigs.. Circulation. Arrhythmia and electrophysiology. 2025. DOI: 10.1161/circep.124.013237.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.